Description

The controller board Words with English Display ,5 seconds fast tin, excellent workmanship, quality and stability, strong power, freely adjust the sleep time to 30 minutes, black brushed aluminum casing, black acrylic panels, beautiful appearance, large joints is no longer a problem

Specifications:  
- Working AC voltage: 100-240V
- Temperature setting range: 150-480 degree, the actual temperature can be 500 degrees
- Sleep Time 1-30 minutes freely adjust
- SIZE:Length:60mm Wide:27mm

Special note: OLED soldering station on a new heater installed being given issue beeps, it does not matter two or three minutes like a new heater will have a process of adaptation, with the aged or used are not new heater temperature is within 5 degrees of beating is normal. After beating aging will be within 1 degree

Basic operation
- Normal mode, the rotary encoder to adjust the temperature, slow turn, every 1 degree grid, fast forward 5 degrees per division.
- Under normal mode,short-press the encoder to enter dormancy, any encoder operation quit ,if the vibration mode is enabled, then the vibration handle to exit Hibernation.
- Normal mode, double-click on the encoder to enter the enhanced mode, any action the encoder exits.
- Sleep mode, press the Mid-button off, power on again or press the power button.
- Normal mode, press the encoder to enter the menu setting mode.
- A long time without entering sleep mode, if not longer into shutdown mode, the two times can be set to enter the menu.

Detailed menu settings meanings:
- The reference voltage, the system in mV. Corresponding to the control board TL431 voltage is consistent, it is recommended to keep the factory parameters.
- The offset voltage. Corresponding to the control board op amp offset voltage, software correction value, the control board using the op amp offset is small, it is recommended to keep the factory parameters.
- Gain adjustment. Corresponding to the control board amplifier magnification, it is recommended to keep the factory parameters.
- The temperature calibration. System for 350 degrees, the global temperature calibration. Other points based linear temperature correction after entering the temperature calibration, corresponding to a professional temperature measurement equipment, slow adjustment parameters until the temperature is 350 degrees for the actual measurement calibration is finished, press Exit.
- The wakeup setting. 0 Do not allow wakeup, 1, vibrations at the handle and encoder operations can wake up the system to sleep. 2, allowing only wake up the system hibernation encoder.
- Sleep time. No action, the system automatically sleep time, in minutes.
- The shutdown time. Sleep, no automatic shutdown wait time in minutes.
- Temperature strengthened. After entering the temperature set to strengthen, increase the temperature set value at the current temperature, in degrees Celsius.
- Strengthening time. After entering the temperature corresponding to strengthen, how long automatic withdrawal temperature enhanced mode. In seconds.
- The alert setup. 1, allowing beep, 0, turn off the buzzer.
- To restore the default. 1 to restore the default parameters, 0 no recovery parameters