{"product_id":"fx3u-48mr-plc-programmable-logic-controller-24-input-24-output-high-speed-counting-analog-quantity","title":"FX3U-48MR PLC Programmable Logic Controller 24 Input 24 Output High-Speed Counting Analog Quantity","description":"\u003cp\u003e\u003cb\u003eVersion Introduction:\u003c\/b\u003e\u003cbr\u003e- It is a bare board only. \u003cbr\u003e- It comes without a base, a shell, RS485 communications, nor a clock.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAdvantages:\u003c\/b\u003e\u003cbr\u003e- 24 inputs 24 outputs\u003cbr\u003e- 6AD+2DA\u003cbr\u003e- High-speed input and output\u003cbr\u003e- Support PID\u003cbr\u003e\u003cbr\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003e- Industrial control board\u003cbr\u003e- Original chip\u003cbr\u003e- Stable performance\u003cbr\u003e- Online download\u003cbr\u003e- Online monitoring\u003cbr\u003e- MR Relay Type: Not support pulse. Can connect AC220 or DC 24V load. Output current up to 5A\u003cbr\u003e- Can be used in various industrial automation control\u003cbr\u003e- Suitable for metallurgy, printing, chemicals, plastics, building materials, home furnishing, packaging, textiles, food\u003cbr\u003e\u003cbr\u003e\u003cb\u003eProduct Parameters:\u003c\/b\u003e\u003cbr\u003e- Product name: industrial control board\u003cbr\u003e- Product model: FX3U-48MR\u003cbr\u003e- Product number: 16600\u003cbr\u003e- Output type: Relay output\u003cbr\u003e- Input points: 24 points\u003cbr\u003e- Output points: 24 points\u003cbr\u003e- Supply voltage: 24V DC\u003cbr\u003e- Output current: 5A\u003cbr\u003e- Analog input: 6AD\u003cbr\u003e- Analog output: 2DA\u003cbr\u003e- High-speed counting: 6-channel 3K. Optional 6-channel 60K \u003cbr\u003e- Pulse output: None\u003cbr\u003e- Floating point: support\u003cbr\u003e- Stepper motor: Not support\u003cbr\u003e- Memory capacity: 8000 steps\u003cbr\u003e- Download method: Direct download\u003cbr\u003e- RS485 communication port: optional\u003cbr\u003e- For MODBUS: optional\u003cbr\u003e- Connect text screen: support\u003cbr\u003e- Connect the touch screen: support\u003cbr\u003e- Programming software: For GX Developer or GX Works2\u003cbr\u003e- Installation method: fixed isolation column installation\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoft Element:\u003c\/b\u003e\u003cbr\u003e- Intermediate relay M: M0-M3071, power-down storage range can be set\u003cbr\u003e- Step point S: S0-1023, power-down saving range can be set to S0-S1023\u003cbr\u003e- 100MS timer: T0-T199, accumulative power-down save T184-T199 \u003cbr\u003e- 10MS timer: T200-T249, accumulative power-off save T246-T249\u003cbr\u003e- 1MS timer: T250-T383, of which T250-255 is cumulative\u003cbr\u003e- 16-bit counter: C0-C199, save C100-199 when power off\u003cbr\u003e- 32-bit counter: C200-C219, save C220-C234 when power off\u003cbr\u003e- 32-bit high-speed counter:\u003cbr\u003eC235-255; C235-240 is a single-phase counter without frequency multiplication;\u003cbr\u003eC241-240 is a single-phase counter, 2 times the frequency;\u003cbr\u003eC247-249 is a two-phase counter without frequency multiplication;\u003cbr\u003eC250-252 is a two-phase counter, 2 times the frequency;\u003cbr\u003eC253-255 is a two-phase counter, 4 times the frequency;\u003cbr\u003e- Register D: D0-D7999, the saving range can be set to D0-7999 after power-off\u003cbr\u003e- Indirect addressing pointer V, Z: V0-7, Z0-7\u003cbr\u003e- P subroutine jump number: P0-63\u003cbr\u003e- I Interrupt: X0-5 external interrupt. Timer interrupt (1MS as a unit). The counter is interrupted.\u003cbr\u003e- Special M element: M8000 is normally closed when running, M8002 is power-on pulse, M8011 is 10Ms pulse, M8012 is 100Ms pulse, M8013 is 1s pulse, and M8014 is minute pulse.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eInstruction List:\u003c\/b\u003e\u003cbr\u003e\u003cu\u003eBasic instructions:\u003c\/u\u003e\u003cbr\u003eLD: Normally open contact at the start of operation\u003cbr\u003eLDI: Normally closed contact at the start of operation\u003cbr\u003eLDP: Rising edge detection operation starts\u003cbr\u003eLDF: Falling edge detection operation starts\u003cbr\u003eAND: series normally open contact\u003cbr\u003eANI: Series normally closed contact\u003cbr\u003eANDP: Series connection detected on rising edge\u003cbr\u003eANDF: Falling edge detection of series connection\u003cbr\u003eOR: Parallel normally open contacts\u003cbr\u003eORI: Parallel normally closed contacts\u003cbr\u003eORP: parallel connection detected by rising edge\u003cbr\u003eORF: Falling edge detection parallel connection\u003cbr\u003eANB: Series connection between circuit blocks\u003cbr\u003eORB: parallel connection between circuit blocks\u003cbr\u003eOUT: Coil output drive\u003cbr\u003eSET: keep the coil action\u003cbr\u003eRST: Release the coil operation hold\u003cbr\u003ePLS: Coil rising edge output\u003cbr\u003ePLF: Coil falling edge output\u003cbr\u003eALT: alternate output\u003cbr\u003eMC: Coil for common string connection point\u003cbr\u003eMCR: Common contact release command\u003cbr\u003eMPS: Operational storage\u003cbr\u003eMRD: storage read\u003cbr\u003eMPP: memory read and reset\u003cbr\u003eINV: Invert the result of the operation\u003cbr\u003eEND: end of program\u003cbr\u003eSTL: start of step ladder diagram\u003cbr\u003eRET: End of step ladder diagram\u003cbr\u003eCALL: call subroutine\u003cbr\u003eSRET: Subroutine return\u003cbr\u003e\u003cbr\u003e\u003cu\u003eProcedure Flow Chart:\u003c\/u\u003e\u003cbr\u003eCJ: Conditional jump\u003cbr\u003eCALL: subroutine call\u003cbr\u003eSRET: Subroutine return\u003cbr\u003eFEND: End of main program\u003cbr\u003e\u003cbr\u003e\u003cu\u003eSend and Compare:\u003c\/u\u003e\u003cbr\u003eCMP: Comparison\u003cbr\u003eZCP: Regional comparison\u003cbr\u003eMOV: transfer\u003cbr\u003eCML: Reverse transmission\u003cbr\u003eBMOV: send together\u003cbr\u003eFMOV: Multicast\u003cbr\u003eXCH: Exchange\u003cbr\u003eBCD: BCD conversion\u003cbr\u003eBIN: BIN conversion\u003cbr\u003e\u003cbr\u003e\u003cu\u003eFour Logical Operations:\u003c\/u\u003e\u003cbr\u003eADD: BIN addition\u003cbr\u003eSUB: BIN subtraction\u003cbr\u003eMUL: BIN multiplication\u003cbr\u003eDIV: BIN division\u003cbr\u003eINC: BIN plus 1\u003cbr\u003eDEC: BIN minus 1\u003cbr\u003eWAND: logical word and\u003cbr\u003eWPR: logical word or\u003cbr\u003eWXOR: logical word exclusive OR\u003cbr\u003eNEG: complement\u003cbr\u003e\u003cbr\u003e\u003cu\u003eCycle Displacement:\u003c\/u\u003e\u003cbr\u003eROR: right shift cycle\u003cbr\u003eROL: Shift left loop\u003cbr\u003eRCR: right shift\u003cbr\u003eRCL: Left shift\u003cbr\u003eSFTL: bit shift left\u003cbr\u003eSFTR: bit shift right\u003cbr\u003e\u003cbr\u003e\u003cu\u003eSpecial Components Instruction:\u003c\/u\u003e\u003cbr\u003eM8000: Normally closed during operation\u003cbr\u003eM8002: Power-on pulse\u003cbr\u003eM8011: 10Ms pulse\u003cbr\u003eM8012: 100Ms pulse\u003cbr\u003eM8013: 1s pulse\u003cbr\u003eM8014: is the minute pulse\u003cbr\u003e\u003cbr\u003eZRST: Batch reset\u003cbr\u003eMEAN: Average\u003cbr\u003eFLT: BIN, integer → 2, hexadecimal floating point number conversion\u003cbr\u003eGRY: BIN, integer → gray code conversion\u003cbr\u003eGBIN: Gray code → BIN, integer\u003cbr\u003e\u003cbr\u003eDHSCS: High-speed comparison set\u003cbr\u003eDHSCR: High-speed comparison reset\u003cbr\u003eSPD: Pulse density, pulse width (pulse interval time) can also be measured\u003cbr\u003ePLSY: Pulse output\u003cbr\u003ePLSV: Pulse output with direction control\u003cbr\u003ePWM: Pulse width modulation, 0-32767us\u003cbr\u003ePLSR: Pulse output with acceleration and deceleration\u003cbr\u003eDRVA: Absolute position control\u003cbr\u003eDRVI: Relative position control\u003cbr\u003eABSD: Cam control (absolute method)\u003cbr\u003e\u003cbr\u003eRS: Serial data transmission\u003cbr\u003eASCI: HEX-ASCII conversion\u003cbr\u003eHEX: ASCII-HEX conversion\u003cbr\u003eCCD: check code\u003cbr\u003ePID: PID calculation\u003cbr\u003eSEGD: BCD to 7-segment digital tube\u003cbr\u003e\u003cbr\u003eECMP: Comparison of binary floating-point numbers\u003cbr\u003eEZCP: Interval comparison of binary floating point numbers\u003cbr\u003eEBIN: decimal floating point number-2, conversion of decimal floating point number\u003cbr\u003eEADD: Addition of binary floating-point numbers\u003cbr\u003eESUB: binary floating-point number subtraction\u003cbr\u003eEMUL: Binary floating point number multiplication\u003cbr\u003eEDIV: Division of binary floating-point numbers\u003cbr\u003eINT: Binary floating point number -BIN, integer conversion\u003cbr\u003eSIN: floating-point number SIN operation\u003cbr\u003eTAN: Floating point number TAN operation\u003cbr\u003eCOS: Floating point COS operation\u003cbr\u003eASIN: floating-point number SIN-1 operation\u003cbr\u003eEXP: binary floating point exponential operation\u003cbr\u003eLOGE: natural logarithm operation of binary floating-point numbers\u003cbr\u003eLOGE10: Commonly used logarithmic operations of binary floating-point numbers\u003cbr\u003e\u003cbr\u003eSWAP: Up and down byte conversion\u003cbr\u003e\u003cbr\u003eSER: data search\u003cbr\u003eALT: alternate output\u003cbr\u003eRAMP: ramp signal\u003cbr\u003eBON: ON bit judgment\u003cbr\u003eSUM: ON digits\u003cbr\u003eANS: Alarm set\u003cbr\u003eANR: Alarm reset\u003cbr\u003eHOUR: Chronograph\u003cbr\u003e\u003cbr\u003eTCMP: Clock data comparison\u003cbr\u003eTRD: Clock data read\u003cbr\u003eTWR: clock data write\u003cbr\u003e\u003cbr\u003eLD=: (S1=(S2)\u003cbr\u003eLD\u0026gt;: (S1)\u0026gt;(S2)\u003cbr\u003eLD\u0026lt;: (S1)\u0026lt;(S2)\u003cbr\u003eLD◇: (S1)≠(S2)\u003cbr\u003eLD≤: (S1)≤(S2)\u003cbr\u003eLD≥: (S1)≥(S2)\u003cbr\u003eAND=: (S1=(S2)\u003cbr\u003eAND\u0026gt;: (S1)\u0026gt;(S2)\u003cbr\u003eAND\u0026lt;: (S1)\u0026lt;(S2)\u003cbr\u003eAND◇: (S1)≠S2)\u003cbr\u003eAND≤: (S1)≤(S2)\u003cbr\u003eAND≥: (S1)≥(S2)\u003cbr\u003eOR=: (S1=(S2)\u003cbr\u003eOR\u0026gt;: (S1)\u0026gt;(S2)\u003cbr\u003eOR\u0026lt;: (S1)\u0026lt;(S2)\u003cbr\u003eOR◇: (S1)≠(S2)\u003cbr\u003eOR≤: (S1)≤(S2)\u003cbr\u003eOR≥: (S1)≥(S2)\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePackage Included:\u003c\/b\u003e\u003cbr\u003e- 1 x Set of PLC Controller\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cb\u003eNote: Programming cable is not included. Please purchase separately.\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003e\u003cimg style=\"width: 750px;\" src=\"https:\/\/www.byimg.com\/catalog\/68716\/68716-01.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width: 877px;\" src=\"https:\/\/www.byimg.com\/catalog\/68716\/68716-02.jpg\"\u003e\u003cbr\u003e\u003cb\u003e\u003cbr\u003eHow To Fix:\u003c\/b\u003e\u003cbr\u003eThe installation method of PLC: The installation method used is to fix the rubber particles on the drill hole. Each PLC board has holes on the four corners for installation. Each board is equipped with 4pcs PC board isolation columns.\u003cbr\u003e\u003cimg style=\"width: 857px;\" src=\"https:\/\/www.byimg.com\/catalog\/68716\/68716-03.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Example:\u003c\/b\u003e\u003cbr\u003e\u003cimg style=\"width: 750px;\" src=\"https:\/\/www.byimg.com\/catalog\/68716\/68716-04.jpg\"\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Thanksbuyer","offers":[{"title":"Default Title","offer_id":40826178011185,"sku":"68716","price":68.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/4790\/6353\/files\/7077351981105_watermarked_0.jpg_0.png?v=1767922009","url":"https:\/\/www.thanksbuyer.com\/de\/products\/fx3u-48mr-plc-programmable-logic-controller-24-input-24-output-high-speed-counting-analog-quantity","provider":"Thanksbuyer Online,SDR Radio, Testers and Measurement devices, Astronomy products,  Audio Amplifer and Decoders","version":"1.0","type":"link"}