{"product_id":"stc-1000-digital-temperature-controller-thermoregulator-thermostat-incubator-for-heating-cooling-12v","title":"STC-1000 Digital Temperature Controller Thermoregulator Thermostat Incubator for Heating Cooling 12V","description":"\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003ePower supply: DC 12V \u003cbr\u003eTemperature range: -50℃～+110℃\u003cbr\u003eResolution: 0.1\u003cbr\u003eAccuracy: ±1℃\u003cbr\u003eRelay output contact capacity: heating: 10A\/240V AC, cooling: 10A\/240V CA\u003cbr\u003eSensor type h: imported NTC sensor, line length 1 meter\u003cbr\u003eShell material: gray ABS flame retardant plastic shell\u003cbr\u003eNet weight: 120g \u003cbr\u003eGross: weight 140g \u003cbr\u003e\u003cbr\u003e\u003cb\u003eLong press Set for 5 seconds to enter internal parameter setting, press up and down to switch P0...P8, press Rst to confirm return\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eP0 cooling, heating mode\u003c\/b\u003e\u003cbr\u003eHigh temperature start is cooling mode, please set to C.\u003cbr\u003eLow temperature start is heating mode, please set to H.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eP1 hysteresis setting\u003c\/b\u003e\u003cbr\u003eIn heating mode (H): measured value ≤ set value-when output difference starts output heating to set value and stops.\u003cbr\u003eIn cooling mode (C): when the measured value ≥ set value + when output difference starts output cooling to set value and stops.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eP2 maximum setting range:\u003c\/b\u003e the highest value does not exceed this value when setting the temperature.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eP3 minimum setting range:\u003c\/b\u003e the minimum value is not lower than this value when setting the temperature.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eP4 temperature correction\u003c\/b\u003e\u003cbr\u003eWhen there is a deviation between the measured temperature and the standard temperature, you can use this function to correct, the temperature after correction = the temperature before correction + the correction value.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eP5 delay start time unit: minutes\u003c\/b\u003e\u003cbr\u003eWhen controlling the cooling of the compressor equipment, the delay time can be set according to the needs. When the controller outputs, the equipment will not start immediately, and it needs to start after running the set delay time.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eP6 high temperature alarm\u003c\/b\u003e\u003cbr\u003eWhen the measured value is greater than this value, the screen displays --- and audible alarm, and the output is forced to be disconnected at the same time.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eP7 data lock function\u003c\/b\u003e\u003cbr\u003eOpen the data lock, you can keep the current settings unchanged, at this time the set temperature and function are invalid, if you need to modify, you need to close the data lock function.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eP8 factory reset\u003c\/b\u003e\u003cbr\u003eLong press SET to switch to P8, press SET once to set to on, press Rst to restore the factory settings.\u003cbr\u003eYou can also press and hold the +- key to hold the power-on self-test and restore factory settings.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cb\u003eInstructions:\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003e1. Please connect the power supply according to the parameters and circuit diagram, and connect the cooling or heating equipment to the output.\u003cbr\u003e2. Enter the internal settings to select heating (enter P0 to select H) or cooling (enter P0 to select C) mode as required.\u003cbr\u003e3. Method of setting temperature: Press Set once to flash, press up and down to set the desired temperature, press Rst to confirm and return.\u003cbr\u003e4. OUT indicator on the panel: flashing means cooling or heating start delay, steady light means output.\u003cbr\u003e5. Nixie tube: display LLL is the sensor open circuit; display HHH is beyond the measurement range, the thermostat will force power off; display --- for high temperature alarm.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cb\u003ePackage List:\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003e1 x Temperature Controller\u003cbr\u003e\u003c\/p\u003e","brand":"Thanksbuyer","offers":[{"title":"Default Title","offer_id":40825424511025,"sku":"66664","price":8.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/4790\/6353\/files\/7077093048369_watermarked_0.jpg_0.png?v=1767969585","url":"https:\/\/www.thanksbuyer.com\/ja\/products\/stc-1000-digital-temperature-controller-thermoregulator-thermostat-incubator-for-heating-cooling-12v","provider":"Thanksbuyer Online,SDR Radio, Testers and Measurement devices, Astronomy products,  Audio Amplifer and Decoders","version":"1.0","type":"link"}