{"product_id":"ws2n-6mr-s-plc-controller-simple-programmable-logic-controller-for-industrial-automation-control","title":"WS2N-6MR-S PLC Controller Simple Programmable Logic Controller For Industrial Automation Control","description":"\u003cp\u003e\u003cb\u003eAdvantages:\u003c\/b\u003e\u003cbr\u003e- Compact size\u003cbr\u003e- Cost-effective\u003cbr\u003e- Support analog quantity \u003cbr\u003e- Support PWM\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFeatures:\u003c\/b\u003e\u003cbr\u003e- Original chip\u003cbr\u003e- Stable performance\u003cbr\u003e- Online download\u003cbr\u003e- Online monitoring\u003cbr\u003e- Can be used in various industrial automation control\u003cbr\u003e- Suitable for metallurgy, printing, chemicals, plastics, building materials, home furnishing, packaging, textiles, food\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e- Model: WS2N-6MR-S\u003cbr\u003e- Input point: 4\u003cbr\u003e- Output point: 2\u003cbr\u003e- Output type: Relay\u003cbr\u003e- Output current: 5A\u003cbr\u003e- Load: 24V, 220V \u003cbr\u003e- High-speed counting: 2\/3K\u003cbr\u003e- Pulse output: None\u003cbr\u003e- Analog quantity input: Optional 2AD 0-10V\u003cbr\u003e- Analog quantity output: None\u003cbr\u003e- For MODBUS: None\u003cbr\u003e- Clock: None\u003cbr\u003e- Base: Optional\u003cbr\u003e- Dimensions: 73* 27 mm (LxW)\u003cbr\u003e- Hole spacing: 21.8*52.5 mm (LxW)\u003cbr\u003e- Size with optional base: 86*31.4*48.4 mm (LxW)\u003cbr\u003e\u003cb\u003e\u003cbr\u003ePackage Included:\u003c\/b\u003e\u003cbr\u003e- 1 x Set of PLC Controller\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSummary of Component Number Assignment and Function:\u003c\/b\u003e\u003cbr\u003eAuxiliary Relay:\u003cbr\u003eGeneral use: M0-M511, 512 points\u003cbr\u003eFor holding: M512-M3071, 2559 points\u003cbr\u003eSpecial use: M8000-M8255, 256 points\u003cbr\u003e\u003cbr\u003eStatus Register:\u003cbr\u003eGeneral use: S0-S127, 128 points\u003cbr\u003eStorage: S128-S899, 772 points\u003cbr\u003e\u003cbr\u003eTimer:\u003cbr\u003e100MS: T0-T199, 200 points\u003cbr\u003e10MS: T200-T245, 46 points\u003cbr\u003e1MS cumulative type: T246-T249, 4 points\u003cbr\u003e100MS cumulative type: T250-T256, 6 points\u003cbr\u003e\u003cbr\u003eCounter:\u003cbr\u003e16-bit increment (for general use): C0-C15, 16 points\u003cbr\u003e16-bit increment (for holding): C16-C99, 84 points\u003cbr\u003e32-bit reversible (generally used): C200-C219, 20 points\u003cbr\u003e32-bit reversible (for holding): C220-C234, 15 points\u003cbr\u003e32-bit reversible (for high-speed retention): C235-C247, 13 points\u003cbr\u003e\u003cbr\u003eData Register:\u003cbr\u003e16-bit general use: DO-D511, 512 points\u003cbr\u003e16-bit retention: D512-D998, 487 points\u003cbr\u003e16-bit special use: D8000-D8255, 256 points\u003cbr\u003eFor 16-bit indexing: V0-V7, Z0-Z7, 15 points\u003cbr\u003e\u003cbr\u003eNested Pointers:\u003cbr\u003eFor skip subroutine, branch: P0-P127, 128 points\u003cbr\u003eMain control: N0-N7, 8 points\u003cbr\u003e\u003cbr\u003eConstant:\u003cbr\u003eDecimal (K): 16 bits -32768 to +32767 (32 bits -2147483648 to +2147483647)\u003cbr\u003eHexadecimal (H): 16 bits: 0~FFFFH (32 bits: 0~FFFFFFFFH)\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecial Soft Component Description:\u003c\/b\u003e\u003cbr\u003eM8000: RUN monitoring (always open during RUN)\u003cbr\u003eM8002: Initialization pulse (normally open scan cycle flag)\u003cbr\u003eM8004: Error prompt (PLC error)\u003cbr\u003eM8012: 100ms clock (oscillate with 100ms period)\u003cbr\u003eM8014: 1min clock (oscillate with 1min period)\u003cbr\u003eM8021: Dislocation mark\u003cbr\u003eM8029: Y0 instruction execution end\u003cbr\u003eM8030: Y1 instruction execution ends\u003cbr\u003e\u003cbr\u003eM8001: RUN monitoring (normally closed during RUN)\u003cbr\u003eM8003: Initialization pulse (normally closed scan cycle flag)\u003cbr\u003eM8011: 10ms clock (oscillate with 10ms period)\u003cbr\u003eM8013: 1s clock (oscillates in 1S period)\u003cbr\u003eM8020: Zero mark (operation mark for application instructions)\u003cbr\u003eM8022: Carry flag\u003cbr\u003eM8040: Transfer prohibited\u003cbr\u003e\u003cbr\u003e\u003cb\u003eInstruction List:\u003c\/b\u003e\u003cbr\u003e27 Basic Sequence Commands:\u003cbr\u003e[LD]: Take\u003cbr\u003e[ANI]: and reverse\u003cbr\u003e[OUT]: Output\u003cbr\u003e[ANB]: Circuit block and\u003cbr\u003e[MRD]: Read stack\u003cbr\u003e[LDP]: Take the rising edge of the pulse\u003cbr\u003e[ANDF]: and pulse falling edge\u003cbr\u003e[RET]: Return\u003cbr\u003e[MC]: Master\u003cbr\u003e\u003cbr\u003e[LDI]: Take reverse\u003cbr\u003e[OR]: or\u003cbr\u003e[SET]: Set\u003cbr\u003e[ORB]: loop block or\u003cbr\u003e[MPP]: Pop\u003cbr\u003e[LDF]: Take the falling edge of the pulse\u003cbr\u003e[ORP]: Or pulse rising edge\u003cbr\u003e[PLS]: rising edge pulse\u003cbr\u003e[MCR]: Master control reset\u003cbr\u003e\u003cbr\u003e[AND]: and\u003cbr\u003e[ORI]: or reverse\u003cbr\u003e[RST]: Reset\u003cbr\u003e[MPS]: Push to stack\u003cbr\u003e[INV]: Invert\u003cbr\u003e[ANDP]: and pulse rising edge\u003cbr\u003e[ORF]: Or pulse falling edge\u003cbr\u003e[PLF]: Falling edge pulse\u003cbr\u003e[END]: End\u003cbr\u003e\u003cbr\u003e1 Step Instruction:\u003cbr\u003e[STL]: Step ladder diagram\u003cbr\u003e\u003cbr\u003eApplication Instruction List:\u003cbr\u003eProcedure Flow Chart:\u003cbr\u003eFNC No.: 00. CJ: Conditional jump\u003cbr\u003eFNC No.: 01. CALL: Subroutine call\u003cbr\u003eFNC No.: 02. SRET: Subroutine return\u003cbr\u003eFNC No.: 03. FEND: End of main program\u003cbr\u003eFNC No.: 04. WDT: Watchdog timer\u003cbr\u003eFNC No.: 05. FOR: Starting point and number of cycles\u003cbr\u003eFNC No.: 06. NEXT: End of the cycle\u003cbr\u003e\u003cbr\u003eTransmission and Comparison:\u003cbr\u003eFNC No.: 07. MOV: Send\u003cbr\u003eFNC No.: 08. BIN: Convert BCD code to binary\u003cbr\u003eFNC No.: 09. CML: Inverted transmission\u003cbr\u003eFNC No.: 10. CMP: Compare\u003cbr\u003eFNC No.: 11. ZCP: Interval comparison\u003cbr\u003eFNC No.: 12. FMOV: Multicast\u003cbr\u003e\u003cbr\u003eArithmetic and Logical Operations:\u003cbr\u003eFNC No.: 13. ADD: Binary addition operation\u003cbr\u003eFNC No.: 14. SUB: Binary subtraction\u003cbr\u003eFNC No.: 15. MUL: Binary multiplication\u003cbr\u003eFNC No.: 16. DIV: Binary division operation\u003cbr\u003eFNC No.: 17. INC: Binary plus 1 operation\u003cbr\u003eFNC No.: 18. DEC: Binary minus 1 operation\u003cbr\u003eFNC No.: 21. WAND: Word logic and\u003cbr\u003eFNC No.: 22. WOR: Word logical OR\u003cbr\u003eFNC No.: 23. WXOR: Logical exclusive OR\u003cbr\u003eFNC No.: 23. NEG: Make up\u003cbr\u003e\u003cbr\u003eCycle and Displacement:\u003cbr\u003eFNC No.: 24. ROR: Shift right loop\u003cbr\u003eFNC No.: 25. ROL: Shift left loop\u003cbr\u003eFNC No.: 26. RCR: Right shift loop with carry\u003cbr\u003eFNC No.: 27. RCL: Shift left loop with carry\u003cbr\u003e\u003cbr\u003eBit Data Processing:\u003cbr\u003eFNC No.: 28. ZRST: Mass reset\u003cbr\u003e\u003cbr\u003eHigh-Speed Processing:\u003cbr\u003eFNC No.: 29. PWM: Pulse width modulation output\u003cbr\u003eFNC No.: 30. PLSY: Specified frequency pulse output\u003cbr\u003eFNC No.: 31. PLSR: With acceleration and deceleration pulse output\u003cbr\u003e\u003cbr\u003eConvenient Instructions:\u003cbr\u003eFNC No.: 32. ALT: Alternate output\u003cbr\u003e\u003cbr\u003eContact Comparison:\u003cbr\u003eFNC No.: 33. LD: (S1)=(S2) when the starting contact is on\u003cbr\u003eFNC No.: 34. LD\u0026gt;: (S1)\u0026gt;(S2) when the starting contact is on\u003cbr\u003eFNC No.: 35. LD\u0026lt;: (S1) \u0026lt;(S2) when the starting contact is on\u003cbr\u003eFNC No.: 36. LD\u0026lt;\u0026gt;: (S1)\u0026lt;\u0026gt;(S2) when the starting contact is on\u003cbr\u003eFNC No.: 37. LD≦: (S1)≦(S2) When the starting contact is on\u003cbr\u003eFNC No.: 38. LD≥: (S1)≥(S2) when the starting contact is on\u003cbr\u003e\u003cbr\u003eFNC No.: 39. AND=: (S1)=(S2) when the series contact is on\u003cbr\u003eFNC No.: 40. AND\u0026gt;: (S1)\u0026gt;(S2) when the series contact is on\u003cbr\u003eFNC No.: 41. AND\u0026lt;: (S1)\u0026lt;(S2) when the series contact is on\u003cbr\u003eFNC No.: 42. AND\u0026lt;\u0026gt;: (S1)\u0026lt;\u0026gt;(S2) when the series contact is on\u003cbr\u003eFNC No.: 43. AND≤: When (S1)≤(S2), the series contacts are connected\u003cbr\u003eFNC No.: 44. AND≥: When (S1)≥(S2), the series contact is on\u003cbr\u003e\u003cbr\u003eFNC No.: 45. OR=: (S1)=(S2) when the parallel contacts are connected\u003cbr\u003eFNC No.: 46. OR\u0026gt;: (S1)\u0026gt;(S2), the parallel contacts are connected\u003cbr\u003eFNC No.: 47. OR\u0026lt;: When (S1)\u0026lt;(S2), the parallel contacts are connected\u003cbr\u003eFNC No.: 48. OR\u0026lt;\u0026gt;: (S1)\u0026lt;\u0026gt;(S2), the parallel contacts are connected\u003cbr\u003eFNC No.: 49. OR≤: When (S1)≤(S2), the parallel contacts are connected\u003cbr\u003eFNC No.: 50. OR≥: When (S1)≥(S2), the parallel contacts are connected\u003cbr\u003e\u003cbr\u003e\u003cb\u003eCommand List is Not Supported in this Version:\u003c\/b\u003e\u003cbr\u003e1. WDT: Watchdog timer refresh\u003cbr\u003e2. CML: Inverted transmission\u003cbr\u003e3. XCH: Exchange\u003cbr\u003e4. FMOV: Multicast\u003cbr\u003e5. SMOV: Bit transfer\u003cbr\u003e6. NEG: Find two's complement\u003cbr\u003e7. REF: Input and output refresh\u003cbr\u003e8. REFF: Input filter time adjustment\u003cbr\u003e9. MTR: Matrix input\u003cbr\u003e10. HSCS: Compare set (for high-speed counting)\u003cbr\u003e11. HSCR: Comparison reset (for high-speed counting)\u003cbr\u003e\u003cbr\u003e12. IST: State initialization\u003cbr\u003e13. ABSD: Cam control (absolute)\u003cbr\u003e14. INCD: Cam control (incremental)\u003cbr\u003e15. DSW: BCD digital switch input\u003cbr\u003e16. SEGL: Seven-segment time-sharing display\u003cbr\u003e17. FROM: BFM read\u003cbr\u003e18. TO: BFM write\u003cbr\u003e19. CCD: proofreading\u003cbr\u003e20. VRRD: Potentiometer variable input\u003cbr\u003e21. VRSC: Potentiometer variable interval\u003cbr\u003e22. ABS: ABS current value read\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cimg style=\"width: 750px;\" src=\"https:\/\/www.byimg.com\/catalog\/68723\/68723-01.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width: 750px;\" src=\"https:\/\/www.byimg.com\/catalog\/68723\/68723-02.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width: 750px;\" src=\"https:\/\/www.byimg.com\/catalog\/68723\/68723-03.jpg\"\u003e\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003cbr\u003eApplication Example:\u003c\/b\u003e\u003cbr\u003e\u003cimg style=\"width: 750px;\" src=\"https:\/\/www.byimg.com\/catalog\/68723\/68723-04.jpg\"\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Thanksbuyer","offers":[{"title":"Default Title","offer_id":40826179059761,"sku":"68723","price":15.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/4790\/6353\/files\/7077353029681_watermarked_0.jpg_0.png?v=1767921575","url":"https:\/\/www.thanksbuyer.com\/ja\/products\/ws2n-6mr-s-plc-controller-simple-programmable-logic-controller-for-industrial-automation-control","provider":"Thanksbuyer Online,SDR Radio, Testers and Measurement devices, Astronomy products,  Audio Amplifer and Decoders","version":"1.0","type":"link"}