{"product_id":"2-axis-solar-tracker-controller-automatic-solar-tracking-system-w-remote-control-dc-2-axis-gimbal","title":"2 Axis Solar Tracker Controller Automatic Solar Tracking System w\/ Remote Control + DC 2 Axis Gimbal","description":"\u003cp\u003e\u003cb\u003e2 Axis Solar Tracker Controller Automatic Solar Tracking System w\/ Remote Control + DC 2 Axis Gimbal\u003c\/b\u003e\u003cbr\u003e\u003cb\u003e\u003cbr\u003eUser Manual of XMYC-3 Solar Tracking Controller:\u003c\/b\u003e\u003cbr\u003eThis \r\ncontroller is a dual-axis sun tracking controller. It uses \r\nhigh-precision inner and outer ring hole sensors to detect the direction\r\n of sunlight. Users can analyzes and judges the sensor signal through \r\nthe single-chip microcomputer circuit on the controller. The \r\ncorresponding motor on the platform can be controlled through the relay \r\ncombination on the circuit board to perform the process of tracking the \r\nsun. At the same time, you can lay it flat in case of wind (wind speed \r\nsensor needs to be purchased), and it can return to the position on \r\ncloudy days or nights. English LCD screen is used to display the \r\ncorresponding parameters, and the parameters can be set by the buttons \r\non the controller or the buttons of an infrared remote control (remote \r\ncontrol needs to be purchased).\u003cbr\u003e\u003cbr\u003eThis controller corresponding \r\nplatform required to be 2-axis platform, the drive motor of platform is \r\nDC brush motor, the motor voltage is 12V or 24V, and current of single \r\nmotor must be less than 15A (each axis with a 10A fuse by default). Four\r\n direction of platform all should have limit switch.\u003cbr\u003e\u003cbr\u003eDC IN: 10-28V; DC OUT=DC IN; I MAX. \u0026lt;15A.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eMain Components of the Tracking Controller:\u003c\/b\u003e\u003cbr\u003e1. Main controller:\u003cbr\u003e\u003cimg style=\"width: 788px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-01.jpg\"\u003e\u003cbr\u003e\u003cbr\u003eMounting\r\n hole of the main controller is 4MM\/0.2\"; Hole space from left to right \r\nis 174MM\/6.9\". Hole spacing from top to bottom is 60MM\/2.4\".\u003cbr\u003e\u003cbr\u003eIt \r\nuses a waterproof box as the shell. When installed vertically, it is \r\nrain-proof and has up to 6 waterproof outlets for line connection. \r\nTerminals are used for wiring on the motherboard. The upper cover has an\r\n on-screen display and six operation buttons, which are convenient for \r\nusers to view parameters and manually operate and set parameters.\u003cbr\u003e\u003cbr\u003e2. Sunlight sensor:\u003cbr\u003e\u003cimg style=\"width: 788px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-02.jpg\"\u003e\u003cbr\u003eIt\r\n has a unique deep-hole internal and external inspection method. Through\r\n the shield of the pheasant cap in the middle, the voltage of sunlight \r\nradiation generated in four directions is transmitted to the motherboard\r\n through a 3-meter-long (9.8ft) 5-core cable. The sensor can be fastened\r\n with two M6 bolts, 40mm\/1.6\" apart. It has a transparent cover and has a\r\n certain protection against dust and rain.\u003cbr\u003e\u003cbr\u003e3. Wind speed sensor (optional):\u003cbr\u003e\u003cimg style=\"width: 788px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-03.jpg\"\u003e\u003cbr\u003eWind\r\n speed sensor is used to detect the wind speed of the environment. When \r\nthe wind speed reaches the protection value set by the controller, the \r\ncontroller control platform will be driven to a position that can \r\nshelter from the wind to protect the platform. The default wind speed \r\nsensor has a cable 3 meter\/9.8 ft in length. (If you want to configure \r\nthe wind speed sensor by yourself, a voltage signal type wind speed \r\nsensor is needed)\u003cbr\u003e\u003cbr\u003e4. IR remote control (optional):\u003cbr\u003e\u003cimg style=\"width: 788px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-04.jpg\"\u003e\u003cbr\u003e\u003cfont color=\"#FF0000\"\u003e\u003cb\u003eNote: The remote control is powered by 2pcs AAA batteries which are not included in the package.\u003c\/b\u003e\u003c\/font\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eFunctions of Controller Board:\u003c\/b\u003e\u003cbr\u003e\u003cimg style=\"width: 788px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-05.jpg\"\u003e\u003cbr\u003e1. Display\u003cbr\u003e2. Remote control receiver\u003cbr\u003e3. Operation button\u003cbr\u003e4. East and west axis output indicator light\u003cbr\u003e5. Buzzer\u003cbr\u003e6. South and north axis output indicator light\u003cbr\u003e7. East-west axis fuse\u003cbr\u003e8. South-north axis fuse\u003cbr\u003e9. Sunlight sensor interface (from left to right: ground, east, west, south, north and +)\u003cbr\u003e10. Wind speed sensor interface (from left to right: power supply V+, GND \u0026amp; signal input)\u003cbr\u003e11. East-west axis motor interface\u003cbr\u003e12. Power supply input (DC 12V or 24V. Left is positive end and the right is negative)\u003cbr\u003e13. South-north axis motor interface\u003cbr\u003e14. Limit terminal interface (from left to right: ground, ground, east, west, south, north, + and +)\u003cbr\u003e\u003cbr\u003e\u003cb\u003eInstallation Method:\u003c\/b\u003e\u003cbr\u003eInstallation of sunlight sensor:\u003cbr\u003eInstall\r\n the sunlight sensor on the platform plane and follow the platform \r\nmovements. Note that it is parallel to the flat surface of the platform.\r\n Note that it is parallel to the flat surface of the platform. When the \r\nplatform is erected, the outlet hole on the detection sensor should face\r\n underground.\u003cbr\u003e\u003cbr\u003eWhen installed in the northern hemisphere, the \r\ndetection sensor should be mounted on the east edge of the north side of\r\n the platform as much as possible. When installed in the southern \r\nhemisphere, the detection sensor should be mounted on the eastern edge \r\nof the south side of the platform.\u003cbr\u003e\u003cimg style=\"width: 788px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-06.jpg\"\u003e\u003cbr\u003eInstallation of main controller:\u003cbr\u003eThe\r\n main control box should be installed near the base post of the \r\nplatform, and does not need to move with the platform. Try to make sure \r\nit's protected from rain, sun and other influences. The outlet hole \r\nfaces downwards to prevent rainwater from flowing in. The installation \r\nshould be located in a position which facilitates observation and \r\noperation.\u003cbr\u003e\u003cimg style=\"width: 788px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-07.jpg\"\u003e\u003cbr\u003e\u003cbr\u003eInstallation of wind speed sensor:\u003cbr\u003e-\r\n The wind speed sensor should be installed near the platform, where it \r\ncan be effectively blown by the wind. Keep away from walls and floors. A\r\n column can be used to support and mount the wind speed sensor.\u003cbr\u003e- Wire the wind speed sensor to the main controller according to the mark, leaving room and installing it firmly.\u003cbr\u003e-\r\n The wiring method of the wind speed sensor: black wire with white \r\nstripes to connect signal input IN, black wire to G, and V+ power supply\r\n terminal disconnected.\u003cbr\u003e- If you are using a wind speed sensor from \r\nanother manufacturers, distinguish the V+, - and signal cable. Wire \r\naccording to the instructions in the manual. The wind speed sensor \r\nterminal V+ on this controller board is the power supply voltage \r\n(12-24V). The signal output must be voltage type and the signal range \r\nmust be less than 5V.\u003cbr\u003e\u003cimg style=\"width: 750px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-08.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eWiring Method of Limit Switch:\u003c\/b\u003e\u003cbr\u003eLimit\r\n switch is essential. There are A and B methods for position limit as \r\nfollows (limit switch needs to be purchased separately).\u003cbr\u003eMethod A: \r\nExternal limit switch is used. The method of external position limit is \r\nto adopt a micro switch with normally closed contact to arrange the four\r\n positions that need to be limited on the platform, so as to directly \r\ncontrol the power supply circuit of the corresponding motor to achieve \r\nthe limit. As shown in the figure below:\u003cbr\u003e\u003cimg style=\"width: 788px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-09.jpg\"\u003e\u003cbr\u003eIn\r\n this way, it is necessary to pay attention to the sufficient carrying \r\ncurrent capacity of the limit switch and the diodes connected in \r\nparallel. If a linear actuator with a limit is used, this method is not \r\nrequired, because the linear actuator is equipped with method A limit \r\ncircuit.\u003cbr\u003e\u003cbr\u003eMethod B: If the limit signal is introduced into the \r\ncontroller to achieve the limit, a limit switch with normally open \r\ncontacts is required. When a certain direction reaches the limit, the \r\nswitch is topped, and the switch will be closed and conducted, and the \r\nground (G) of the limit terminal is shorted with the terminal in the \r\ncorresponding direction, and the output in this direction will be \r\nstopped.\u003cbr\u003e\u003cbr\u003e\u003cimg style=\"width: 788px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-10.jpg\"\u003e\u003cbr\u003e\u003cbr\u003eThe\r\n controller can also be connected to a three-wire NPN proximity switch. \r\nWhen using this kind of switch as a limit, its power supply + end can be\r\n connected to the + end of the limit terminal, and the other wiring is \r\nthe same as that of method B. Note that the top is the sensing area. \r\nWhen there is metal within 5mm, it will output a limit signal.\u003cbr\u003e\u003cimg style=\"width: 788px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-11.jpg\"\u003e\u003cbr\u003eIn\r\n the case of separate power supply without connecting to the controller \r\nboard, the two-axis drive motor should be able to drive the platform to \r\nmove smoothly within the corresponding range. In this case, the motor \r\ncan be connected to the motor terminal of the corresponding axis on the \r\ncontrol board. Wrong connection of east-west axis motor and north-south \r\naxis motor should be avoided.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eRunning and Debugging:\u003c\/b\u003e\u003cbr\u003eAfter\r\n confirming that the sunlight sensor, wind speed sensor, limit switch, \r\nand two-axis motors are connected, a power supply can be connected to \r\nthe controller board for debugging. The power supply voltage is 12V or \r\n24V (subject to the rated voltage of the motor used). The supply current\r\n should be sufficient for the maximum current demand of the two motors. \r\nTurn on the power, the buzzer will sound once, at this time the \r\ncontroller should be powered to work, and the screen will display:\u003cbr\u003e\u003cimg style=\"width: 368px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-12.jpg\"\u003e\u003cbr\u003e\u003cbr\u003eThe\r\n controller then will enter various states based on specific sensor \r\nfeedback parameters. But at this point, we should first test whether the\r\n orientation of the motor is correct. So you have to do manual test \r\nfirst. Press SET button once to enter the following MT page:\u003cbr\u003e\u003cimg style=\"width: 554px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-13.jpg\"\u003e\u003cbr\u003e\u003cbr\u003eAt\r\n this time, buttons →\/←\/↓\/↑ can control the platform to move \r\neast\/west\/south\/north respectively, and the screen will display E\/W\/S\/N.\r\n If the movement direction of the platform does not match the direction \r\nof manual control, please switch the corresponding wiring. Test the full\r\n range of activities of the platform with manual functions, including \r\nthe limit state function, and test it normally for subsequent work.\u003cbr\u003e\u003cbr\u003eWhen\r\n the platform is manually controlled, the corresponding output indicator\r\n light on the controller board will be turned on. Press QUIT button to \r\nexit the manual mode.\u003cbr\u003e\u003cbr\u003eWhen the button is pressed, the screen \r\nbackground light will be turned on and turned off after 10 seconds. If \r\nyou press the QUIT button for five seconds, you can turn the background \r\nlight on or off for a long time.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eParameter Settings:\u003c\/b\u003e\u003cbr\u003eAfter\r\n making sure that the motor is wired correctly, we then go to the \r\nparameter settings and perform the necessary checks and settings on some\r\n parameters. In the non-manual control interface, press and hold the SET\r\n button for 5 seconds and release it, and the device will enter the \r\nparameter setting page. Note that the time parameter is in seconds. The \r\nthreshold value unit V is voltage volt.\u003cbr\u003e\u003cbr\u003eSpecial note: In the \r\nfollowing parameter setting interface, you can switch parameter items by\r\n pressing buttons →\/←. Press the ↓\/↑ button to add\/subtract parameters. \r\nPress and hold the buttons to quickly add\/subtract parameters, and press\r\n the QUIT button to exit and save the parameters. In order to facilitate\r\n the understanding of the meaning of the parameters, the following \r\nparameters are not expressed in order. Please check it by yourself while\r\n setting.\u003cbr\u003e\u003cbr\u003eV2\/T3\/T4\/T5\/T6\/T7 (Wind speed protection related parameters):\u003cbr\u003e\u003cimg style=\"width: 788px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-14.jpg\"\u003e\u003cbr\u003eWhen\r\n the signal voltage from the wind speed sensor is higher than V2, it \r\nwill enter the wind speed protection control state, and the order is as \r\nfollows:\u003cbr\u003e(1) Immediately drive the platform to the east T3 time, and at the same time, execute the platform to the north T5 time\u003cbr\u003e(2)\r\n Then the platform is executed to the west T4 time, and at the same \r\ntime, after the execution of T5 is completed, the platform is executed \r\nto the south T6 time.\u003cbr\u003e(3) After performing the above process, T7 is \r\nthe time to keep locking. During T7 time, the unit remains in standby \r\nmode. If the wind speed continues to exceed the V2 value, the T7 time \r\nwill be full again.\u003cbr\u003e(4) If the wind speed is lower than V2, it will \r\nexit the wind speed protection state after the T7 time is over. If it is\r\n cloudy during the T7 countdown after the wind speed protection action \r\nis completed, the device will also be locked and will not exit the wind \r\nspeed protection state. The maximum parameter value can be set to 999 \r\nand the minimum parameter value can be set to 1. By setting the above \r\nparameters reasonably, the platform can be executed to the angle and \r\nposition desired by the user when the wind speed exceeds the limit. The \r\ndefault configuration of the wind speed sensor signal voltage and wind \r\nspeed conversion formula: V*25=m\/s; V*25=m\/s。\u003cbr\u003eFor example, the \r\nF-number displayed by the wind speed sensor = 0.2 means that the current\r\n wind speed is about 5 m\/s. If the V2 value is set to 0.18, the wind \r\nspeed threshold is set to 4.5 m\/s.\u003cbr\u003e\u003cbr\u003eV1\/V3\/T13\/TX\/TY parameters:\u003cbr\u003e\u003cimg style=\"width: 788px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-15.jpg\"\u003e\u003cbr\u003eWhen\r\n the voltage detected by the sunlight sensor in either direction is \r\nhigher than V3, it will judge that the weather is sunny and it will be \r\ntimed. If the time that is continuously higher than V3 reaches the T13 \r\ntime (seconds), it will enter the sunny tracking state. The controller \r\ncontrols the action of each axis motor to align with the sun. V1 is the \r\ntracking accuracy, and the smaller the value, the higher the accuracy. \r\nHowever, the mechanical accuracy of the platform is required to reach a \r\ncertain level. The significance of the TX\/TY parameter is that in the \r\nprocess of automatic tracking of the sun, when aiming at the sun, an \r\nintermittent time is set to avoid the frequent repetition of the \r\ntracking caused by small light changes. That is, after aligning with the\r\n sun, the axis enters a sleep time. And then it will re-detect the \r\nposition of the sun for tracking. The sun also moves very slowly, so \r\nsetting intervals can also save electricity.\u003cbr\u003eTX: When the east-west axis is aligned, TX is the intermittent waiting time for entry.\u003cbr\u003eTY: When the north-south axis is aligned, TY is the intermittent waiting time for entry.\u003cbr\u003eBy setting the above parameters reasonably, you can ensure that the controller can track quickly and accurately on sunny days.\u003cbr\u003e\u003cbr\u003eT8\/T9\/T10\/T11\/T12 (platform homing parameter setting on cloudy day or at night):\u003cbr\u003e\u003cimg style=\"width: 788px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-16.jpg\"\u003e\u003cbr\u003eWhen\r\n the voltage in any direction detected by the sunlight detector is lower\r\n than V3, the sunlight is judged to be weak. At this point, it will \r\nsleep in place and enter the T18 countdown (seconds). During the \r\ncountdown time, if the sunlight value has not returned above V3, after \r\nthe countdown ends, it will perform a homing action in the following \r\norder:\u003cbr\u003e(1) Run T9 time to the east, and at the same time, run T11 time to the north.\u003cbr\u003e(2) Then execute the T10 time to the west. After the execution of T11 is completed, the T12 time to the south will be executed.\u003cbr\u003e\u003cbr\u003eT8\r\n can be set to a maximum of 9990, and other parameter values can be set \r\nto a maximum of 999 and a minimum of 1. By setting the above parameters \r\nreasonably, the platform can be assigned to the angle or position \r\ndesired by the user when there is weak sunshine or at night.\u003cbr\u003e\u003cimg style=\"width: 361px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-17.jpg\"\u003e\u003cbr\u003eAfter the parameter setting is complete, press the QUIT button to exit and save the parameters.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eLogical sequence in which the devices work automatically:\u003c\/b\u003e\u003cbr\u003eAfter\r\n the device is powered on, the controller will automatically control the\r\n data transmitted by the sensor. It is divided into the following cases:\u003cbr\u003eSH:\r\n If the voltage detected by the sunlight sensor in any direction is \r\nhigher than V3, it will enter the sunny day automatic tracking state \r\nafter accumulating the time set by the timer T13 parameter:\u003cbr\u003e\u003cimg style=\"width: 591px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-18.jpg\"\u003e\u003cbr\u003eIn\r\n this state, the controller compares the voltages on the east and west \r\nsides and the north and south sides of sunlight sensor to control the \r\nplatform. When an axis is aligned, it will enter the TX\/TY intermittent \r\nwaiting time. After this time countdown is over, the controller will \r\ncompare and control again, enabling the tracking process.\u003cbr\u003e\u003cbr\u003eSL: When the voltage detected by the sunlight sensor in any direction is lower than V3, it will enter a cloudy or night state:\u003cbr\u003e\u003cimg style=\"width: 579px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-19.jpg\"\u003e\u003cbr\u003eFirst,\r\n it goes into the T8 delay. In T8 time, if the voltage is higher than \r\nV3, it will exit this state. If the time that continues to be lower than\r\n V3 reaches the T8 time, the prescribed action is executed:\u003cbr\u003eAfter the\r\n east T9 time, the west T10 time is executed, and the north T11 time is \r\nexecuted, and then the south T12 time is executed. In this state, the \r\nbuzzer will sound at a certain frequency to alert. When the action is \r\nfinished, it will enter the state of waiting for sunlight.\u003cbr\u003e\u003cbr\u003eFS: When the wind speed detected by the wind speed sensor is higher than V2, it will enter the wind speed homing state:\u003cbr\u003e\u003cimg style=\"width: 579px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-20.jpg\"\u003e\u003cbr\u003eWhen\r\n the signal voltage of the wind speed sensor is higher than the set V2 \r\nand lasts for 3 seconds, the wind speed is judged to be overrun, and the\r\n controller performs the wind speed homing action in the following \r\norder:\u003cbr\u003eT3 time to the east, then T4 time to the west, T5 time to the \r\nnorth, and then T6 time to the south. In this state, the buzzer will \r\nsound at a certain frequency to alert.\u003cbr\u003e\u003cbr\u003eOnce the execution is \r\ncomplete, it goes into T7 locking countdown. During the countdown time, \r\nif the signal voltage of the wind speed sensor exceeds V2 again, the T7 \r\ncountdown will be re-timed and it will be locked again. If it's cloudy \r\nat this time, it will be locked until sunlight returns.\u003cbr\u003e\u003cbr\u003eIn the \r\nabove working state, the screen can display various parameters \r\nalternately through buttons →\/←: the voltage of the sunshine sensor in \r\nthe east, west, north and south, the signal voltage of the wind speed \r\nsensor, the current power supply voltage, etc.\u003cbr\u003e\u003cbr\u003eRegarding night homing and windy homing, the sequence logic is as follows:\u003cbr\u003eT9 or T3 to the east and then T10 or T4 to the west:\u003cbr\u003e\u003cimg style=\"width: 632.821px; height: 240.45px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-21.jpg\"\u003e\u003cbr\u003e\u003cbr\u003eT11 or T5 to the north, T12 or T6 to the south:\u003cbr\u003e\u003cimg style=\"width: 578px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/86084\/75047-22.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eExplanation of the Parameters of LCD screen:\u003c\/b\u003e\u003cbr\u003eAT: Automatic tracking status. In this state, the device will automatically track the sun.\u003cbr\u003eTX:\r\n It is a waiting period when the east-west axis is aligned in the \r\nautomatic-tracking state. During the period, the device will not \r\noperate. Recommendation: 100\u003cbr\u003eTY: It is a waiting period when the \r\nnorth-south axis of the automatic-tracking status is aligned. During the\r\n period, the device will not operate. Recommendation: 100\u003cbr\u003eE: East; W: West; S: South; N: North (indicates that the device moves in the corresponding direction)\u003cbr\u003eV: The real-time voltage of power supply.\u003cbr\u003eFS: Wind speed exceeds the set value and it will enter the state of leveling and homing when encountering wind.\u003cbr\u003eFSLOCK: The locked state after the wind speed is reset.\u003cbr\u003eF: Real-time wind speed voltage. The unit is V.\u003cbr\u003eSH: Automatic tracking on sunny days.\u003cbr\u003eMT:\r\n Manual operation status. In this state, the 1\/2\/3\/4 buttons of the \r\nremote control correspond to manual movement in the \r\nnorth\/south\/west\/east direction.\u003cbr\u003eSL: Weak sunshine. The device will go to sleep and wait for the sunlight to appear again.\u003cbr\u003eT3:\r\n The time value in seconds for the device to drive eastward when \r\nexecuting the specified action of wind speed exceeding the limit. The \r\nunit is seconds.\u003cfont color=\"#FF0000\"\u003e\u003cb\u003e (Recommended setting value: the time taken by the platform from east to west * 1.2 times)\u003c\/b\u003e\u003c\/font\u003e\u003cbr\u003eT4:\r\n When performing the specified action of exceeding the wind speed limit,\r\n it is the time value of the drive device to the west after T3. The unit\r\n is seconds.\u003cb\u003e\u003cfont color=\"#FF0000\"\u003e (Recommended setting: The time it \r\ntakes for the platform to move from west to east to the east-west axis \r\nposture you want the platform to perform)\u003c\/font\u003e\u003c\/b\u003e\u003cbr\u003eT5: When \r\nperforming the specified action of exceeding the wind speed limit, it is\r\n the time value of the device to drive north. The unit is seconds. \u003cfont color=\"#FF0000\"\u003e\u003cb\u003e(Recommended setting value: the time taken by the platform from south to north * 1.2 times)\u003c\/b\u003e\u003c\/font\u003e\u003cbr\u003eT6:\r\n When performing the specified action of exceeding the wind speed limit,\r\n T6 is the time value for driving device to the south after T5 time. The\r\n unit is seconds.\u003cfont color=\"#FF0000\"\u003e\u003cb\u003e (Recommended setting: the \r\ntime it takes for the platform to move from north to south to the \r\nnorth-south axis attitude you want the platform to perform)\u003c\/b\u003e\u003c\/font\u003e\u003cbr\u003eT7:\r\n After performing the specified action of exceeding the wind speed \r\nlimit, T7 is the self-locking time of the controller. This function is \r\nto prevent the wind speed effect from being intermittent and causing the\r\n unit to perform frequent tracking. During the self-locking time, if the\r\n wind speed exceeds the value again, the time will be immediately \r\nre-timed, so that the device does not operate frequently. The unit is \r\nseconds. \u003cfont color=\"#FF0000\"\u003e\u003cb\u003e(Recommended setting: 600)\u003c\/b\u003e\u003c\/font\u003e\u003cbr\u003eT8: Delay value of weak sunlight duration.\u003cfont color=\"#FF0000\"\u003e\u003cb\u003e (Recommended setting: 1800)\u003c\/b\u003e\u003c\/font\u003e\u003cbr\u003eT9:\r\n When performing a specified action with weak sunlight, T9 is the time \r\nvalue for the device to drive eastward. The unit is seconds.\u003cfont color=\"#FF0000\"\u003e\u003cb\u003e (Recommended setting value: the time taken by the platform from east to west * 1.2 times)\u003c\/b\u003e\u003c\/font\u003e\u003cbr\u003eT10:\r\n When performing a specified action with weak sunlight, T10 is the time \r\nvalue for the device to drive to the west after T9. The unit is seconds.\r\n \u003cb\u003e\u003cfont color=\"#FF0000\"\u003e(Recommended setting: The time it takes for \r\nthe platform to move from west to east to the east-west axis posture you\r\n want the platform to perform)\u003c\/font\u003e\u003c\/b\u003e\u003cbr\u003eT11: It is the time for the device to drive north when performing a specified action with weak sunlight. The unit is seconds. \u003cfont color=\"#FF0000\"\u003e\u003cb\u003e(Recommended setting value: the time taken by the platform from south to north * 1.2 times)\u003c\/b\u003e\u003c\/font\u003e\u003cbr\u003eT12:\r\n It is the time for the for the device to drive to the south after T11 \r\nwhen performing the specified action in weak sunlight. The unit is \r\nseconds. \u003cfont color=\"#FF0000\"\u003e\u003cb\u003e(Recommended setting: the time it \r\ntakes for the platform to move from north to south to the north-south \r\naxis attitude you want the platform to perform)\u003c\/b\u003e\u003c\/font\u003e\u003cbr\u003eT13: It is the set continuous delay time for sunlight recovery after the occurrence of weak sunlight. The unit is seconds. \u003cfont color=\"#FF0000\"\u003e\u003cb\u003e(Recommended setting: 10)\u003c\/b\u003e\u003c\/font\u003e\u003cbr\u003eV1:\r\n Tracking accuracy setting. This value is the voltage value of the \r\ntracking accuracy range. When the voltages detected in the east\/west and\r\n south\/north differ by V, the controller believes that the device needs \r\nto be moved or aimed at the sun. The smaller the value, the higher the \r\naccuracy, and vice versa. It needs to be set according to the \r\ncharacteristics of the platform\u003cb\u003e\u003cfont color=\"#FF0000\"\u003e (Recommended value: 0.06)\u003c\/font\u003e\u003c\/b\u003e\u003cbr\u003eV2:\r\n Wind speed control voltage. This value is the threshold set by the \r\ncontroller. When the voltage output by the wind speed sensor is higher \r\nthan this value, the controller deems it necessary to immediately \r\nprescribe action to protect the platform \u003cfont color=\"#FF0000\"\u003e\u003cb\u003e(Recommended\r\n setting value: The parameter corresponding table of the wind speed \r\nsensor shall prevail. The recommended setting value of the sensor \r\nconfigured by our company is 0.15)\u003c\/b\u003e\u003c\/font\u003e\u003cbr\u003eV3: Weak sunshine \r\ncontrol voltage. It is the threshold value set by the controller. When \r\nnone of the voltages in the four directions of the sunlight sensor is \r\nhigher than this value, the controller thinks that the current sunlight \r\nis weak and has no power generation value, and cancels tracking. If the \r\ndevice is still tracking the sun on cloudy days, you can turn this value\r\n up appropriately so that the controller can judge that it is cloudy. \u003cfont color=\"#FF0000\"\u003e\u003cb\u003e(Recommended setting: 1.80)\u003c\/b\u003e\u003c\/font\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAttention:\u003c\/b\u003e\u003cbr\u003e1. When debugging and operating the platform, personnel should stay away from the platform to avoid accidental injury.\u003cbr\u003e2. Avoid installing, inspecting or debugging equipment during thunderstorms.\u003cbr\u003e3. When wiring, the power supply should be disconnected to avoid short circuit damage to the equipment.\u003cbr\u003e4.\r\n The controller should be installed in a location that is protected from\r\n the sun and rain and is not easy to be disturbed. The outlet hole is \r\ninstalled facing downward.\u003cbr\u003e5. If the fuse is blown out, it means that\r\n the motor may have a high current. A detailed inspection is required \r\nbefore reusing this device.\u003cbr\u003e6. Regularly inspect the sunlight sensor for dirt and for accidental movement.\u003cbr\u003e7. Manually rotate the wind speed sensor regularly for 5 seconds to observe whether the wind speed protection action is normal.\u003cbr\u003e8.\r\n When the power supply is insufficient, the controller will restart as \r\nsoon as the motor outputs. At this time, you should check whether the \r\npower supply is insufficient or the motor output is overloaded.\u003cbr\u003e9. \r\nWhen there is smoke and odor, the controller may be irreversibly \r\ndamaged. Power supply should be cut off immediately, discontinued, and \r\ntechnical support should be sought.\u003cbr\u003e10. When installing outdoors, be \r\nsure to pay attention to the upper and lower covers, which should be \r\ninstalled tightly and not leaking. Be careful not to poke the seal off.\u003cbr\u003e\u003cbr\u003eOur company reserves the right to change the hardware and software design of this controller without prior notice.\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eFeatures of Two Axis Gimbal:\u003c\/b\u003e\u003cbr\u003e- Load capacity: not exceeding 4kg\/8.8lb at DC 24V; not over 2.5kg\/5.5lb at DC 12V\u003cbr\u003e- With limit switches: Automatic protection will be enabled when it reaches a specific position\u003cbr\u003e- As soon as the gimbal is powered on, it will start to work. When the direction of the current is changed, the direction of movement will be reversed. The motor speed is 1RPM\u003cbr\u003e- Its body is made of all-metal, and the bracket is made of ultra thick aluminum alloy with excellent stability\u003cbr\u003e- Ultra-low speed gear worm motor, all metal gears and torque of 35g\/0.08lb\u003cbr\u003e- With self-locking, it can achieve all-round dual-axis tracking. There are two horizontal and two vertical limit switches to avoid tangled wires\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecifications of Two Axis Gimbal:\u003c\/b\u003e\u003cbr\u003e- Motor name: Gear motor with worm and worm wheel\u003cbr\u003e- Motor voltage: 5V-12V-24V\u003cbr\u003e- Motor speed: 1RPM\u003cbr\u003e- Motor power: 30W\u003cbr\u003e- Horizontal rotation angle: 340°\u003cbr\u003e- Gimbal specifications: Base 86mm\/3.4\", height 420mm\/16.5\", and worm 240mm\/9.4\"\u003cbr\u003e- Vertical rotation angle: 120°\u003cbr\u003e- Load capacity at 24V: ≤4kg\/8.8lb\u003cbr\u003e- Load capacity at 12V: ≤2.5kg\/5.5lb\u003cbr\u003e- Bracket material: aluminum alloy + 3mm\/0.1\" steel plate\u003cbr\u003e- Gearbox material: metal gears\u003cbr\u003e- Gimbal mounting panel: 40 x 100mm\/1.6 x 3.9\"\u003cb\u003e\u003cbr\u003e\u003cbr\u003ePackage Included:\u003c\/b\u003e\u003cbr\u003e- 1 x Main Controller + Sunshine Sensor\u003cbr\u003e- 1 x Remote Control\u003cbr\u003e- 1 x 2-Axis Gimbal\u003cbr\u003e\u003cbr\u003e\u003cfont color=\"#FF0000\"\u003e\u003cb\u003eNote:\u003cbr\u003e- The wind speed sensor pictured is not included, for demonstration purposes only. Thank you for your understanding!\u003cbr\u003e- Batteries are not included. 2pcs AAA batteries are needed for the remote control.\u003cbr\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/font\u003e\u003cb\u003ePackaging Details:\u003cbr\u003e\u003c\/b\u003e- G.W.: 1.95kg\u003cb\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/b\u003e\u003cimg style=\"width: 800px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/88324\/88511-01.jpg\"\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg style=\"width: 800px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/88324\/88511-02.jpg\"\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg style=\"width: 800px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/88324\/88511-03%202.jpg\"\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Thanksbuyer Online,SDR Radio, Testers and Measurement devices, Astronomy products, Audio Amplifer and Decoders","offers":[{"title":"Default Title","offer_id":41029114069041,"sku":"88511","price":159.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/4790\/6353\/files\/1714961464-13.jpg?v=1780391138","url":"https:\/\/www.thanksbuyer.com\/ko\/products\/2-axis-solar-tracker-controller-automatic-solar-tracking-system-w-remote-control-dc-2-axis-gimbal","provider":"Thanksbuyer Online,SDR Radio, Testers and Measurement devices, Astronomy products,  Audio Amplifer and Decoders","version":"1.0","type":"link"}