{"product_id":"4-20ma-signal-generator-passive-signal-generator-calibration-device-analog-transmitter","title":"4-20mA Signal Generator Passive Signal Generator Calibration Device Analog Transmitter","description":"\u003cp\u003e\u003cb\u003e4-20mA Signal Generator Passive Signal Generator Calibration Device Analog Transmitter\u003cbr\u003e\u003cbr\u003eParameters:\u003c\/b\u003e\u003cbr\u003e- Power Supply: 10-30V\u003cbr\u003e- Output Signal: 4-20mA\u003cbr\u003e- Minimum Resolution: 0.01mA\u003cbr\u003e- Accuracy: 0.2%\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePackage Included:\u003c\/b\u003e\u003cbr\u003e- 1 x Signal Generator\u003cbr\u003e\u003cbr\u003e\u003cimg style=\"width: 800px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/67639\/67639-01.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eThree Working Modes:\u003c\/b\u003e\u003cbr\u003e- Mode 1: Manual adjustment of analog quantity. Voltage\/current value can be adjusted by the knob to follow the change in real time.\u003cbr\u003e- Mode 2 (PC): Automatic rise and fall linear output. According to the maximum and minimum values of set parameters, the product will complete the change from the minimum value to the maximum value within a specified period, and the cycle continues.\u003cbr\u003e- Mode 3 (PS): Automatic step up and down output. According to the maximum value and minimum value of set parameters and the value of each step increase or decrease, the product will complete the change from the minimum value to the maximum within the specified period, and the cycle continues.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eParameter Settings (Press \u003c\/b\u003e\u003cb\u003e\u003cimg style=\"width: 31.1667px; height: 26.4917px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/67639\/67639-02.JPG\"\u003e for \u003c\/b\u003e\u003cb\u003e3s to enter menu shown as bellow): \u003c\/b\u003e\u003cbr\u003erun: Working mode. Multiple choice\u003cbr\u003eSHEn: Engineering quantity enable (only valid when analog quantity is manually adjusted). Setting range OFF\/ON\u003cbr\u003eSH-H: The upper limit of engineering quantity. Setting range: -1999 to 9999, the default is 100.0\u003cbr\u003eSH-L: Lower limit of engineering quantity. Setting range: -1999 to 9999, the default is 0.0\u003cbr\u003eSH-P: The position of the decimal point of the engineering quantity. 0-2\u003cbr\u003eSAEn: Automatically save the set value flag. Setting range OFF\/ON\u003cbr\u003eAUTO: Parameter setting for automatic rise and fal. Multiple choice\u003cbr\u003e----Exit the menu\u003cbr\u003e\u003cb\u003e\u003cbr\u003eParameter Modification:\u003c\/b\u003e\u003cbr\u003e- Rotate the knob to select parameters, and press SET button to enter parameter modification.\u003cbr\u003e- Press SET to save the modified parameter value.\u003cbr\u003e- Value setting: Press the knob and turn to select the number of digits to be set.\u003cbr\u003e\u003cb\u003e\u003cbr\u003eDetailed Explanation of Multiple Choice Menu:\u003c\/b\u003e\u003cbr\u003erun: Working mode.\u003cbr\u003eAdjust the knob to run, press SET button to enter, there are three options:\u003cbr\u003e4-20mA: manual mode\u003cbr\u003ePC (Mode 2): Automatic up down linear output\u003cbr\u003ePS (Mode 3): Automatic step up and down output\u003cbr\u003e\u003cbr\u003e\u003cb\u003eUsing Method:\u003c\/b\u003e\u003cbr\u003eRotate the knob to select input mode. After pressing SET button, the meter will automatically exit the menu and enter the working mode immediately.\u003cbr\u003e\u003cbr\u003eIf you select Mode 2 or Mode 3, the meter is in a paused state and you need to press the start key to start working.\u003cbr\u003e\u003cbr\u003eAUTO: Parameter Setting for Automatic Up and Down\u003cbr\u003eAdjust the knob to AUTO, press SET key to enter, the parameters are as follows:\u003cbr\u003ePo-L: Automatic rise and fall minimum value, the setting range is the signal range of the corresponding model\u003cbr\u003ePo-H: the maximum value of automatic rise and fall, the setting range is the signal range of the corresponding model\u003cbr\u003ePo-M: Automatic up and down waveform mode. First rise and then fall, rise, fall, three modes are optional\u003cbr\u003ePC-S: Time setting of automatic rise and fall linear output (PC)\u003cbr\u003ePS-S: Time and step value of automatic rise and fall stepping output (PS)\u003cbr\u003e----Return to superior\u003cbr\u003e\u003cbr\u003e\u003cb\u003eDetailed Explanation of Time Setting Parameters of PC-S Automatic Rise \u0026amp; Fall Linear Output (PC):\u003c\/b\u003e\u003cbr\u003ePCT1 cycle, coefficient 1, maximum 9999, unit: second\u003cbr\u003ePCT2 period, coefficient 2, maximum 9999, unit: second\u003cbr\u003ePCSt starts the PC program directly\u003cbr\u003e----Return to superior\u003cbr\u003e\u003cbr\u003e\u003cb\u003eCoefficient Description:\u003c\/b\u003e\u003cbr\u003eOne rise and fall cycle=PCT1*PCT2.\u003cbr\u003eThe two coefficients are to increase the length of time, because only 4 digits are available.\u003cbr\u003eFor example, PCT1=60, PCT2=1, period 60*1=60 seconds, Po-M=first rise and then fall sequence. At the beginning of the program, the output is the Po-L value, after 30 seconds it rises to the Po-H value, and then it drops to the Po-L value from 30 seconds, so that a process completes a cycle.\u003cbr\u003e\u003cbr\u003ePo-M=First rise and then fall sequence. At the beginning of the program, the output is the Po-L value, after 30 seconds it rises to the Po-H value, and then it drops to the Po-L value from 30 seconds. This process completes a cycle.\u003cbr\u003e\u003cbr\u003ePo-M= rising sequence, the program output is the Po-L value at the beginning, after 60 seconds, it rises to the Po-H value, and then immediately jumps to the Po-L value, so that a process completes a cycle.\u003cbr\u003e\u003cbr\u003ePo-M=decline sequence, the program output is Po-H value at the beginning, after 60 seconds, it drops to Po-L value, then immediately returns to Po-H value, such a process completes one cycle.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eDetailed Explanation of Time Setting Parameters of PS-S Automatic Rise \u0026amp; Fall Step Output (PS):\u003c\/b\u003e\u003cbr\u003ePST1 cycle, coefficient 1, maximum 9999, unit: second\u003cbr\u003ePST2 cycle, coefficient 2, maximum 9999, unit: second\u003cbr\u003ePSSU step value. The setting range is the signal range of the corresponding model\u003cbr\u003ePSSt directly starts the Ps program\u003cbr\u003e----Return to superior\u003cbr\u003e\u003cbr\u003e\u003cb\u003eCoefficient Description:\u003c\/b\u003e\u003cbr\u003eA signal value step time=PST1*PST2.\u003cbr\u003eThe two coefficients are to increase the length of time because only 4 digits are available.\u003cbr\u003eFor example, PST1=4, PST2=1, PSAU=4.00, step time 4*1=4 seconds.\u003cbr\u003ePo-M=First rise and then fall sequence. At the beginning of the program, the output is the Po-L value. After 4 seconds, it increases by 4.00, and then cyclically increases to the Po-H value, and then cyclically decreases to the Po-L value. This process completes a cycle.\u003cbr\u003e\u003cbr\u003ePo-M = rising sequence, the program outputs the Po-L value at the beginning, after 4 seconds it increases by 4.00, and then increases to the Po-H value in a loop, and then immediately jumps to the Po-L value, so that a process completes one cycle.\u003cbr\u003e\u003cbr\u003ePo-M=decline sequence, the output of the program is the Po-H value at the beginning, after 4 seconds, the decrease is increased by 4.00, and then the cycle is reduced to the Po-L value, and then it immediately jumps to the Po-H value, such a process completes a cycle .\u003cbr\u003e\u003cbr\u003e\u003cb\u003eCalibration:\u003c\/b\u003e\u003cbr\u003eAfter the device is powered on, it is connected to a meter, and current value can be measured normally, and then press and hold \u003cimg style=\"width: 85.1667px; height: 33.9282px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/67639\/67639-03.JPG\"\u003e for 3s to enter calibration menu.\u003cbr\u003e\u003cbr\u003eRotate the knob to calibrate the point, press \u003cb\u003e\u003cimg style=\"width: 31.1667px; height: 26.4917px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/67639\/67639-02.JPG\"\u003e\u003c\/b\u003e to enter the modification, and press \u003cb\u003e\u003cimg style=\"width: 31.1667px; height: 26.4917px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/67639\/67639-02.JPG\"\u003e\u003c\/b\u003eagain after modification.\u003cbr\u003e\u003cbr\u003e20CA: Calibrate 20ma. Modify this parameter to 20ma.\u003cbr\u003e4CA: Calibrate 4ma. Modify this parameter to 4ma.\u003cbr\u003e----Exit\u003cbr\u003eAfter adjustment, save and exit!\u003cbr\u003e\u003c\/p\u003e","brand":"Thanksbuyer Online,SDR Radio, Testers and Measurement devices, Astronomy products, Audio Amplifer and Decoders","offers":[{"title":"Default Title","offer_id":41019904327729,"sku":"67639","price":13.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/4790\/6353\/files\/1613638362-7.jpg?v=1780046183","url":"https:\/\/www.thanksbuyer.com\/ko\/products\/4-20ma-signal-generator-passive-signal-generator-calibration-device-analog-transmitter","provider":"Thanksbuyer Online,SDR Radio, Testers and Measurement devices, Astronomy products,  Audio Amplifer and Decoders","version":"1.0","type":"link"}