{"product_id":"gl001-500-1000ml-min-hydrogen-rich-water-electrolytic-cell-module-pem-hydrogen-and-oxygen-generator-for-pure-water","title":"GL001 500-1000ML\/min Hydrogen Rich Water Electrolytic Cell Module PEM Hydrogen and Oxygen Generator for Pure Water","description":"\u003cp\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003cbr\u003e- Model: GL001\u003cbr\u003e- Hydrogen yield: 35±5ml\/min for hydrogen; 17±2ml\/min for oxygen\u003cbr\u003e- Working medium: pure water, complies with GB17323\u003cbr\u003e- Product size: 90 x 72 x 40mm\u003cbr\u003e- Mounting hole size: 4 x diameter of 3.5 punched hole (can punch M4 screws)\u003cbr\u003e- Inlet and outlet diameter: 1\/4 inch quick connector\u003cbr\u003e- Power supply type: constant current power supply\u003cbr\u003e- Rated input voltage\/current: DC15V\/5A\u003cbr\u003e- Acceptable operating voltage\/current range: ≤24V\/5-7A\u003cbr\u003e- Working water: pure water, TDS\u0026lt;10ppm\u003cbr\u003e- Working temperature: 0 - 45℃\u003cbr\u003e- Working pressure: ≤0.3MPa\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOutput Characteristics:\u003c\/b\u003e\u003cbr\u003e- Flow rate of hydrogen water: 600 - 1000ml\/min\u003cbr\u003e- Dissolved hydrogen content: working pressure of 0 - 0.3MPa, hydrogen content of 600 - 1500ppb\u003cbr\u003e- Normal working voltage\/current: 2.0 - 5V \/ 5 - 7A\u003cbr\u003e- Surface temperature: \u0026lt; 45℃\u003cbr\u003e- Protection: over-voltage protection, over-current protection, over-temperature protection.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eEnvironment Requirements:\u003c\/b\u003e\u003cbr\u003e- Working temperature: 0℃ to 40℃\u003cbr\u003e- Storage temperature: 0℃ to 40℃\u003cbr\u003e- Relative humidity: 5% - 85%\u003cbr\u003e- Altitude: ≤3000m\u003cbr\u003e- Cooling method: water cooling\u003cbr\u003e- Life time: Input 15V\/5A constant current power supply, water quality within 5ppm, continuous operation for a total of 1000h, with a reduction rate of not less than 50%.\u003cbr\u003e- Waterproof level: non-waterproof\u003cbr\u003e- Electrical safety: the power supply is DC low-voltage weak current input, with no risk of electric shock.\u003cbr\u003e- Safety distance: The surface temperature of products that have been working for a long time is relatively high, and they must be at least 3cm away from plastic parts. Products with poor ventilation must be cooled by air cooling.\u003cbr\u003e- Water pressure resistance: it can withstand a maximum working water pressure of 0.3MPa and a maximum burst pressure of 0.8MPa\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePackage Included:\u003c\/b\u003e\u003cbr\u003e- 1 x Electrolytic Cell Module\u003cbr\u003e\u003cbr\u003e\u003cb\u003eConnection Explanation:\u003c\/b\u003e\u003cbr\u003e- 1\/4\" quick connectors are standard for inlet and outlet connectors.\u003cbr\u003e- The cathode and anode of the electrolytic cell must work simultaneously with water supply.\u003cbr\u003e- The power input wire must use composite specification pure copper core wire, and be wired according to the positive\/negative pole identification. It must not be reversed, as reversing may burn the electrode; M3 screws\/nuts\/washers can be used for wiring, and they must be firmly fixed, otherwise there is a risk of sparking and catching fire.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eMounting:\u003c\/b\u003e\u003cbr\u003e- The product can be directly fixed and installed.\u003cbr\u003e- To ensure the water level in the electrolytic cell, the product must be installed vertically, with the inlet located below and the outlet located above.\u003cbr\u003e- To ensure sufficient water supply flow, the water supply needs to have pressure, but the pressure should not exceed 0.3MPa.\u003cbr\u003e- The product will generate high temperatures during operation, and appropriate ventilation space should be maintained. It is not allowed to directly contact plastic parts, and a fan should be used for air cooling if necessary.\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePrecaution:\u003c\/b\u003e\u003cbr\u003e- Water supply source: compliant with GB17323 purified water to ensure that the water quality input into the electrolytic cell meets the requirements, and the TDS of the water quality does not exceed 10ppm.\u003cbr\u003e- When using, ensure that the electrolytic cell is fully soaked in water before powering on to avoid damaging the membrane components due to water shortage. Water shortage will damage the electrodes.\u003cbr\u003e- Water supply pressure requirements: It is recommended to use a circulating pump for water supply. And ensure smooth water supply through pipelines.\u003cbr\u003e- Water supply system monitoring: Water supply sources must undergo water shortage and quality monitoring, such as water level sensors in water tanks, water flow sensors in water supply pipelines, and water quality sensors in water supply pipelines, to prevent water shortage, dry burning, or substandard water quality issues.\u003cbr\u003e- If there is icing during the storage and transportation process, it must be placed in a warm room before use, until it is confirmed that the ice in the electrolytic cell and pipeline has completely thawed before being powered on for use. If it is an outdoor equipment, temperature control and monitoring must be adopted to ensure that the pipeline does not freeze.\u003cbr\u003e- If the electrolytic cell has not been used for more than 6 months, it is recommended to perform activation treatment before installation.\u003cbr\u003e- Power parameters must meet the requirements of section 3.1: For large-sized electrolytic cells with a large working current, it is recommended to adopt a soft start gradually increasing current working mode to reduce impact and effectively protect the electrolytic cell and power supply.\u003cbr\u003e- Note that the +\/- pole of the power input should not be reversed, and the wiring should be firm.\u003c\/p\u003e\u003cp\u003e\u003cimg style=\"width: 750px;\" src=\"https:\/\/www.comseek.com\/image\/catalog\/101632\/101632-01.jpg\"\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Thanksbuyer","offers":[{"title":"Default Title","offer_id":41028988764209,"sku":"101632","price":36.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/4790\/6353\/files\/1776929133-1.jpg?v=1780374808","url":"https:\/\/www.thanksbuyer.com\/ko\/products\/gl001-500-1000ml-min-hydrogen-rich-water-electrolytic-cell-module-pem-hydrogen-and-oxygen-generator-for-pure-water","provider":"Thanksbuyer Online,SDR Radio, Testers and Measurement devices, Astronomy products,  Audio Amplifer and Decoders","version":"1.0","type":"link"}