{"product_id":"ecg-signal-generator-ecg-simulator-generate-respiratory-waveform-multiple-waveforms-skx-2000d","title":"ECG Signal Generator ECG Simulator Generate Respiratory Waveform Multiple Waveforms SKX-2000D","description":"\u003cp\u003e\u003cb\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eFeatures:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e- Large capacity enables long running time.  \u003cbr\u003e- Rechargeable type. The voltage of charger cannot be higher than 4.2V. Please not over discharge. \u003cbr\u003e- 10 universal ECG adapters can be connected to the lead wires of various electrocardiographs and monitors.\u003cbr\u003e- Green light of the charger indicates that charging is completed. The brighter the red light, the low the electricity. \u003cbr\u003e- Automatic shutdown when there is lower electricity. \u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eFunctions:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e- Produce normal ECG waveform \u003cbr\u003e- Produce positive and negative triangle waveform\u003cbr\u003e- Produce analog triangle waveform for arrhythmia waveform\u003cbr\u003e- Produce square wave to measure scanning speed\u003cbr\u003e- Generate sine wave to measure amplitude frequency characteristics \u003cbr\u003e- Generate simulated respiratory waveform\u003cbr\u003e- Generate calibration waveform (1MV)\u003cbr\u003e- Set signal amplitude \u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eWaveform Introduction:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cb\u003e1.Normal ECG Waveform:\u003c\/b\u003e\u003cbr\u003e★ Heart Rate Setting Range: 10-200bpm (Initial value: 60 bpm)\u003cbr\u003e★ The signal amplitude is fixed.\u003cbr\u003e\u003cbr\u003e\u003cb\u003e2.Positive and Negative Triangular Waveform:\u003c\/b\u003e\u003cbr\u003e★ Frequency Range: 10-300bpm (Initial value: 75 bpm)\u003cbr\u003e★ Amplitude Range: 0.1-4Mv (10:0.1mV, 400:4mV)\u003cbr\u003e★ 2 Modes: Mode 1: Forward Waveform. Mode 2: Negative Waveform. Select via combination key. \u003cbr\u003e\u003cb\u003e\u003cbr\u003e3.Arrhythmia Waveform:\u003c\/b\u003e\u003cbr\u003e★ Frequency Range: 20-250bpm (Initial value: 80 bpm)\u003cbr\u003e★ Amplitude Range: 0.1-4Mv (10:0.1mV, 400:4mV);\u003cbr\u003e★ 2 Modes: Mode 1: Big waveform is downwards. Mode 2: Big waveform is upwards. Select via combination key.\u003cbr\u003e\u003cbr\u003e\u003cb\u003e4.Square Wave:\u003c\/b\u003e\u003cbr\u003e★ Frequency Range: 0.1Hz-10Hz (10:0.1Hz 100:10Hz); (Initial value: 1 Hz)\u003cbr\u003e★ Amplitude Range: 0.1-4Mv (10:0.1mV, 400:4mV)\u003cbr\u003e\u003cb\u003e\u003cbr\u003e5.Sine Waveform:\u003c\/b\u003e\u003cbr\u003e★ Frequency Range: 1-100Hz (Initial value: 10 Hz)\u003cbr\u003e★ Amplitude Range: 0.1-4Mv (10:0.1mV, 400:4mV)\u003cbr\u003e★ The waveform is superimposed by DC component in the range of 0.1mV-3mV (10:0.1mV, 400:4mV)\u003cbr\u003e★ Select parameters to be changed by combination key. Mode 1: Frequency. Mode 2: Superimposed DC Component (10:0.1mV, 400:4mV). \u003cbr\u003e\u003cbr\u003e\u003cb\u003e6.Simulated Respiratory Waveform:\u003c\/b\u003e\u003cbr\u003e★ Frequency Range: 5-100 beats \/ min. (Initial value: 10 bpm)\u003cbr\u003e★ Respiratory lead is RA-LL. If the default setting of the monitor respiratory lead is not the two leads, please switch the monitor settings or change the connection of the lead wire. \u003cbr\u003e★ At this moment, its heart rate value is fixed. \u003cbr\u003e\u003cbr\u003e\u003cb\u003e7.Calibration Waveform:\u003c\/b\u003e\u003cbr\u003e★ Amplitude: 1mV. Width: 100mS \u003cbr\u003e★ Frequency Range: 60bpm\u003cbr\u003e\u003cbr\u003e\u003cb\u003e8.Signal Amplitude Settings: \u003c\/b\u003e\u003cbr\u003e★ Amplitude Range: 0.1mV-4mV (10:0.1mV, 400:4mV); (Initial value: 100)\u003cbr\u003e★ Please note that the amplitude setting will affect all waveforms except the ECG waveform.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cb\u003ePackage Included:\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003e- 1 x ECG Simulator \u003cbr\u003e- 1 x Instructions \u003cbr\u003e- 1 x Charger \u003cbr\u003e- 1 x Waveform Comparison Chart \u003cbr\u003e- 1 x Quality Certificate \u003cbr\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cb\u003eNote: \u003cbr\u003e- After the simulator is powered on, a normal ECG waveform with a waveform of 1 is automatically generated. II lead is an amplitude-corresponding lead with a default amplitude of 1 mV. \u003cbr\u003e- When there is no operation for 24 hours, it will enter into standby state automatically and you can trigger any button to reset the time to zero. \u003cbr\u003e- The color of its rear cover the the device might be changed. Please make sure you don't mind before purchasing. Thank you!\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Thanksbuyer","offers":[{"title":"Default Title","offer_id":40824622579761,"sku":"63030","price":135.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/4790\/6353\/files\/7076833624113_watermarked_0.jpg_0.png?v=1768027102","url":"https:\/\/www.thanksbuyer.com\/products\/ecg-signal-generator-ecg-simulator-generate-respiratory-waveform-multiple-waveforms-skx-2000d","provider":"Thanksbuyer Online,SDR Radio, Testers and Measurement devices, Astronomy products,  Audio Amplifer and Decoders","version":"1.0","type":"link"}