{"product_id":"fx1n-30mr-plc-controller-board-programmable-logic-controller-direct-download-relay-output-with-shell","title":"FX1N-30MR PLC Controller Board Programmable Logic Controller Direct Download Relay Output With Shell","description":"\u003cp\u003e\u003cb\u003eAdvantages:\u003c\/b\u003e\u003cbr\u003e- 16 inputs 14 outputs \u003cbr\u003e- Online monitoring\u003cbr\u003e- Direct download\u003cbr\u003e- NTC temperature measurement\u003cbr\u003e- MR Relay: Not support pulse. Can connect AC220 or DC 24V load. Output current up to 5A\u003cbr\u003e\u003cbr\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003e- Original chip\u003cbr\u003e- Stable performance\u003cbr\u003e- Online download\u003cbr\u003e- Online monitoring\u003cbr\u003e- Can be used in various industrial automation control\u003cbr\u003e- Suitable for metallurgy, printing, chemicals, plastics, building materials, home furnishing, packaging, textiles, food\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e- Item name: Industrial controller board\u003cbr\u003e- Model: FX1N-30MR\u003cbr\u003e- Product number: 12600\u003cbr\u003e- Output type: Relay output\u003cbr\u003e- Input point: 16 points \u003cbr\u003e- Output point: 14 points\u003cbr\u003e- Power supply voltage: 24V DC \u003cbr\u003e- Output current: 5A\u003cbr\u003e- Analog quantity input: Optional 3AD 0-10V\/4-20MA\/NTC 10K\u003cbr\u003e- Analog quantity output: Optional 2DA 0-10V\u003cbr\u003e- High-speed counting: 2-channel 3K\u003cbr\u003e- Pulse output: None\u003cbr\u003e- Floating point: Not support \u003cbr\u003e- Stepper motor: Not support\u003cbr\u003e- Internal storage capacity: 8000 steps \u003cbr\u003e- Download way: Direct download\u003cbr\u003e- RS485 communications port: Optional\u003cbr\u003e- For MODBUS: Optional\u003cbr\u003e- Connect text screen: Support\u003cbr\u003e- Connect touch screen: Support\u003cbr\u003e- Programming software: For GX Developer or GX Works2\u003cbr\u003e- Installation way: Fixed isolation column installation\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePackage Included:\u003c\/b\u003e\u003cbr\u003e- 1 x Set of PLC Controller\u003cbr\u003e\u003cbr\u003e\u003cb\u003eInstruction List\u003c\/b\u003e\u003cbr\u003eBasic Sequence Commands:\u003cbr\u003eLD: take\u003cbr\u003eLDI: Take reverse\u003cbr\u003eAND: and\u003cbr\u003eANI: and reverse\u003cbr\u003eOR: or\u003cbr\u003eORI: or reverse\u003cbr\u003eOUT: output\u003cbr\u003eSET: set\u003cbr\u003eRST: reset\u003cbr\u003eANB: Loop block and\u003cbr\u003e0RB: loop block or\u003cbr\u003eMPS: Push to stack\u003cbr\u003eMRD: read stack\u003cbr\u003eMPP: Unstack\u003cbr\u003eINV: reverse\u003cbr\u003eLDP: Take the rising edge of the pulse\u003cbr\u003eLDF: Take the falling edge of the pulse\u003cbr\u003eANDP: and pulse rising edge\u003cbr\u003eANDF: and pulse falling edge\u003cbr\u003eORP: Or pulse rising edge\u003cbr\u003eORF: OR pulse falling edge\u003cbr\u003eRET: return\u003cbr\u003ePLS: rising edge pulse\u003cbr\u003ePLF: Falling edge pulse\u003cbr\u003eMC: Master\u003cbr\u003eMCR: Master control reset\u003cbr\u003eEND: end\u003cbr\u003e\u003cbr\u003eStep Instructions:\u003cbr\u003eSTL: Step ladder diagram \u003cbr\u003e\u003cbr\u003eProcedure Flow Chart:\u003cbr\u003eCJ: Conditional jump\u003cbr\u003eCALL: subroutine call\u003cbr\u003eSRET: Subroutine return\u003cbr\u003eIRET: Interrupt return\u003cbr\u003eEI: Open interrupt\u003cbr\u003eDI: Close interrupt\u003cbr\u003eFEND: End of main program\u003cbr\u003eWDT: Watchdog timer refresh\u003cbr\u003eFOR: starting point and number of loops\u003cbr\u003eNEXT: the end of the loop\u003cbr\u003e\u003cbr\u003eSend and Compare:\u003cbr\u003eMOV: transfer\u003cbr\u003eCML: Inverted transmission\u003cbr\u003eXCH: Exchange\u003cbr\u003eBCD: Binary conversion to BCD\u003cbr\u003eBIN: Convert BCD code to binary\u003cbr\u003eCMP: Comparison\u003cbr\u003eZCP: Interval comparison\u003cbr\u003eFMOV: Multicast\u003cbr\u003eSMOV: Bit transfer\u003cbr\u003eBMOV: batch delivery\u003cbr\u003e\u003cbr\u003eArithmetic and Logical Operations:\u003cbr\u003eADD: Binary addition operation\u003cbr\u003eSUB: Binary subtraction operation\u003cbr\u003eMUL: Binary multiplication operation\u003cbr\u003eDIV: Binary division operation\u003cbr\u003eINC: Binary plus 1 operation\u003cbr\u003eDEC: Binary minus 1 operation\u003cbr\u003eWAND: Word Logic And\u003cbr\u003eWOR: Word logical OR\u003cbr\u003eWXOR: Word logic exclusive OR\u003cbr\u003eNEG: Find two's complement\u003cbr\u003e\u003cbr\u003eBit Data Processing:\u003cbr\u003eZRST: Word shift left\u003cbr\u003eDECO: Decoding\u003cbr\u003eENCO: Encoding\u003cbr\u003e\u003cbr\u003eCycle and Displacement:\u003cbr\u003eSFTR: bit shift right\u003cbr\u003eSFTL: bit shift left\u003cbr\u003eSFWR: FIFO (first in first out) write\u003cbr\u003eSFRD: FIFO (first in first out) read\u003cbr\u003e\u003cbr\u003eHigh-Speed Processing:\u003cbr\u003eREF: Input and output refresh\u003cbr\u003eREFF: Input filter time adjustment\u003cbr\u003eMTR: Matrix input\u003cbr\u003eHSCS: Compare set (for high-speed counting)\u003cbr\u003eHSCR: Comparison reset (for high-speed counting)\u003cbr\u003eSPD: Pulse density\u003cbr\u003ePLSY: Specified frequency pulse output\u003cbr\u003ePWM: Pulse width modulation output\u003cbr\u003ePLSR: With acceleration and deceleration pulse output\u003cbr\u003e\u003cbr\u003eConvenient Instructions:\u003cbr\u003eIST: State initialization\u003cbr\u003eABSD: Cam control (absolute)\u003cbr\u003eINCD: Cam control (incremental)\u003cbr\u003eALT: Alternate output\u003cbr\u003eRAMP: ramp signal\u003cbr\u003e\u003cbr\u003ePeripheral I\/O Device Port:\u003cbr\u003eDSW: BCD digital switch input\u003cbr\u003eSEGL: Seven-segment code time-sharing display\u003cbr\u003eFROM: BFM read\u003cbr\u003eTO: BFM write\u003cbr\u003e\u003cbr\u003ePeripheral Equipment:\u003cbr\u003eRS: Serial data transmission\u003cbr\u003ePRUN: octal digit transmission (#)\u003cbr\u003eASCI: Convert hexadecimal number to ASCI code\u003cbr\u003eHEX: Convert ASCI code to hexadecimal number\u003cbr\u003eCCD: Check\u003cbr\u003eVRRD: Potentiometer variable input\u003cbr\u003eVRSC: Potentiometer variable interval\u003cbr\u003ePID: PID calculation\u003cbr\u003e\u003cbr\u003ePositioning:\u003cbr\u003eABS: ABS current value read\u003cbr\u003eZRN: Return to origin\u003cbr\u003ePLSV: Variable speed pulse output\u003cbr\u003eDRVI: Relative position control\u003cbr\u003eDRVA: Absolute position control\u003cbr\u003e\u003cbr\u003eClock Operation:\u003cbr\u003eTCMP: Clock data comparison\u003cbr\u003eTZCP: Clock data interval comparison\u003cbr\u003eTADD: Clock data addition\u003cbr\u003eTSUB: Clock data subtraction\u003cbr\u003eTRD: Clock data read\u003cbr\u003eTWR: Clock data write\u003cbr\u003eHOUR: Chronograph\u003cbr\u003e\u003cbr\u003eContact Comparison:\u003cbr\u003eLD: (S1)=(S2) when the starting contact is on\u003cbr\u003eLD\u0026gt;: (S1)\u0026gt;(S2) when the starting contact is on\u003cbr\u003eLD\u0026lt;: (S1) \u0026lt;(S2) when the starting contact is on\u003cbr\u003eLD\u0026lt;\u0026gt;: (S1)\u0026lt;\u0026gt;(S2) when the starting contact is on\u003cbr\u003eLD≦: (S1)≦(S2) When the starting contact is on\u003cbr\u003eLD≥: (S1)≥(S2) when the starting contact is on\u003cbr\u003e\u003cbr\u003eAND=: (S1)=(S2) when the series contact is on\u003cbr\u003eAND\u0026gt;: (S1)\u0026gt;(S2) when the series contact is on\u003cbr\u003eAND\u0026lt;: (S1)\u0026lt;(S2) when the series contact is on\u003cbr\u003eAND\u0026lt;\u0026gt;: (S1)\u0026lt;\u0026gt;(S2) when the series contact is on\u003cbr\u003eAND≤: When (S1)≤(S2), the series contacts are connected\u003cbr\u003eAND≥: When (S1)≥(S2), the series contact is on\u003cbr\u003e\u003cbr\u003eOR=: (S1)=(S2) when the parallel contacts are connected\u003cbr\u003eOR\u0026gt;: (S1)\u0026gt;(S2), the parallel contacts are connected\u003cbr\u003eOR\u0026lt;: When (S1)\u0026lt;(S2), the parallel contacts are connected\u003cbr\u003eOR\u0026lt;\u0026gt;: (S1)\u0026lt;\u0026gt;(S2), the parallel contacts are connected\u003cbr\u003eOR≤: When (S1)≤(S2), the parallel contacts are connected\u003cbr\u003eOR≥: When (S1)≥(S2), the parallel contacts are connected\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecial Component Description:\u003c\/b\u003e\u003cbr\u003eM8000: RUN monitoring (always open during RUN)\u003cbr\u003eM8002: Initialization pulse (normally open scan cycle flag)\u003cbr\u003eM8004: Error prompt (PLC error)\u003cbr\u003eM8012: 100ms clock (oscillate with 100ms period)\u003cbr\u003eM8014: 1 min clock (oscillate with 1 min period)\u003cbr\u003eM8021: Dislocation mark\u003cbr\u003eM8029: instruction execution end\u003cbr\u003eM8034: disable output\u003cbr\u003e\u003cbr\u003eM8001: RUN monitoring (normally closed during RUN)\u003cbr\u003eM8003: Initialization pulse (normally closed scan cycle flag)\u003cbr\u003eM8011: 10ms clock (oscillate with 10ms period)\u003cbr\u003eM8013: 1s clock (oscillates in 1S period)\u003cbr\u003eM8020: Zero mark (operation mark for application instructions)\u003cbr\u003eM8022: Carry flag\u003cbr\u003eM8033: Memory storage\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSummary of Soft Element Function:\u003c\/b\u003e\u003cbr\u003eAuxiliary Relay:\u003cbr\u003eGeneral use: M0-M383, 384 points\u003cbr\u003eKeep use: M384-M1535, 1152 points\u003cbr\u003eSpecial use: M8000-M8255, 256 points\u003cbr\u003e\u003cbr\u003eStatus Register:\u003cbr\u003eInitial state: S0-S9, 10 points\u003cbr\u003eGeneral status: S10-S127, 118 points\u003cbr\u003eSave area: S128-S899, 772 points\u003cbr\u003e\u003cbr\u003eTimer:\u003cbr\u003e100MS: T0-T199, 200 points\u003cbr\u003e10MS: T200-T245, 46 points\u003cbr\u003e1MS cumulative type: T246-T249, 4 points\u003cbr\u003e100MS cumulative type: T250-T256, 6 points\u003cbr\u003e\u003cbr\u003eCounter:\u003cbr\u003e16-bit increment (general use): C0-C15, 16 points\u003cbr\u003e16-bit increment (for holding): C16-C199, 184 points\u003cbr\u003e32-bit reversible (general use): C200-C219, 20 points\u003cbr\u003e32-bit reversible (for holding): C220-C234, 15 points\u003cbr\u003e32-bit reversible (for high-speed retention): C235-C255, 8 points\u003cbr\u003e\u003cbr\u003eData Register:\u003cbr\u003e16-bit general use: D0-D127, 128 points\u003cbr\u003e16-bit retention: D128-D2300, 2172 points\u003cbr\u003e16-bit special use: D8000-D8255, 20 points\u003cbr\u003eFor 16-bit indexing: V0-V7 Z0-Z7, 15 points\u003cbr\u003e\u003cbr\u003eNested Pointers:\u003cbr\u003eFor skip subroutine, branch: P0-P127, 128 points\u003cbr\u003eMain control: N0-N7, 8 points\u003cbr\u003e\u003cbr\u003eConstant:\u003cbr\u003eDecimal (K): 16-32768 to +32767, 32-bit\u003cbr\u003eHexadecimal (H): 16 bits: 0~FFFFH, 32 bits: 0~FFFFFFFFH\u003cbr\u003e\u003cimg style=\"width: 750px;\" src=\"https:\/\/www.byimg.com\/catalog\/68727\/68727-01.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width: 750px;\" src=\"https:\/\/www.byimg.com\/catalog\/68727\/68727-02.jpg\"\u003e\u003cbr\u003e\u003cb\u003eHow to Fix?\u003c\/b\u003e\u003cbr\u003eThe installation method of PLC: The installation method used is to fix rubber particles on the drill hole. Each PLC board has holes on the four corners for installation. Each board is equipped with 4pcs PC board isolation columns.\u003cbr\u003e\u003c\/p\u003e","brand":"Thanksbuyer","offers":[{"title":"Default Title","offer_id":40826179747889,"sku":"68728","price":47.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/4790\/6353\/files\/7077353717809_watermarked_0.jpg_0.png?v=1767921285","url":"https:\/\/www.thanksbuyer.com\/products\/fx1n-30mr-plc-controller-board-programmable-logic-controller-direct-download-relay-output-with-shell","provider":"Thanksbuyer Online,SDR Radio, Testers and Measurement devices, Astronomy products,  Audio Amplifer and Decoders","version":"1.0","type":"link"}