{"product_id":"fx1n-30mt-plc-controller-programmable-logic-controller-direct-download-transistor-output-with-shell","title":"FX1N-30MT PLC Controller Programmable Logic Controller Direct Download Transistor Output With Shell","description":"\u003cp\u003e\u003cb\u003eAdvantages:\u003c\/b\u003e\u003cbr\u003e- 16 inputs 14 outputs \u003cbr\u003e- Online monitoring\u003cbr\u003e- Direct download\u003cbr\u003e- NTC temperature measurement\u003cbr\u003e- MT transistor type: Support pulse output. Only support DC24V load. Output current up to 1A\u003cbr\u003e\u003cbr\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003e- Original chip\u003cbr\u003e- Stable performance\u003cbr\u003e- Online download\u003cbr\u003e- Online monitoring\u003cbr\u003e- Can be used in various industrial automation control\u003cbr\u003e- Suitable for metallurgy, printing, chemicals, plastics, building materials, home furnishing, packaging, textiles, food\u003cbr\u003e\u003cb\u003e\u003cbr\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e- Item name: Industrial controller board\u003cbr\u003e- Model: FX1N-30MT\u003cbr\u003e- Product number: 13200\u003cbr\u003e- Output type: Transistor output\u003cbr\u003e- Input point: 16 points \u003cbr\u003e- Output point: 14 points\u003cbr\u003e- Power supply voltage: 24V DC \u003cbr\u003e- Output current: 1A\u003cbr\u003e- Analog quantity input: Optional 3AD 0-10V\/4-20MA\/NTC 10K\u003cbr\u003e- Analog quantity output: Optional 3AD 0-10V\u003cbr\u003e- High-speed counting: 2-channel 3K\u003cbr\u003e- Pulse output: 2-channel 3K\u003cbr\u003e- Floating point: Not support \u003cbr\u003e- Support Stepper motor: 2pcs \u003cbr\u003e- Internal storage capacity: 8000 steps \u003cbr\u003e- Download way: Direct download\u003cbr\u003e- RS485 communications port: Optional\u003cbr\u003e- For MODBUS: Optional\u003cbr\u003e- Connect text screen: Support\u003cbr\u003e- Connect touch screen: Support\u003cbr\u003e- Programming software: For GX Developer or GX Works2\u003cbr\u003e- Installation way: Fixed isolation column installation\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePackage Included:\u003c\/b\u003e\u003cbr\u003e- 1 x Set of PLC Controller\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInstruction List: \u003c\/b\u003e\u003cbr\u003eBasic Sequence Commands:\u003cbr\u003eLD: take\u003cbr\u003eLDI: Take reverse\u003cbr\u003eAND: and\u003cbr\u003eANI: and reverse\u003cbr\u003eOR: or\u003cbr\u003eORI: or reverse\u003cbr\u003eOUT: output\u003cbr\u003eSET: set\u003cbr\u003eRST: reset\u003cbr\u003eANB: Loop block and\u003cbr\u003e0RB: loop block or\u003cbr\u003eMPS: Push to stack\u003cbr\u003eMRD: read stack\u003cbr\u003eMPP: Unstack\u003cbr\u003eINV: reverse\u003cbr\u003eLDP: Take the rising edge of the pulse\u003cbr\u003eLDF: Take the falling edge of the pulse\u003cbr\u003eANDP: and pulse rising edge\u003cbr\u003eANDF: and pulse falling edge\u003cbr\u003eORP: Or pulse rising edge\u003cbr\u003eORF: OR pulse falling edge\u003cbr\u003eRET: return\u003cbr\u003ePLS: rising edge pulse\u003cbr\u003ePLF: Falling edge pulse\u003cbr\u003eMC: Master\u003cbr\u003eMCR: Master control reset\u003cbr\u003eEND: end\u003cbr\u003e\u003cbr\u003eStep Instructions:\u003cbr\u003eSTL: Step ladder diagram \u003cbr\u003e\u003cbr\u003eProcedure Flow Chart:\u003cbr\u003eCJ: Conditional jump\u003cbr\u003eCALL: subroutine call\u003cbr\u003eSRET: Subroutine return\u003cbr\u003eIRET: Interrupt return\u003cbr\u003eEI: Open interrupt\u003cbr\u003eDI: Close interrupt\u003cbr\u003eFEND: End of main program\u003cbr\u003eWDT: Watchdog timer refresh\u003cbr\u003eFOR: starting point and number of loops\u003cbr\u003eNEXT: the end of the loop\u003cbr\u003e\u003cbr\u003eSend and Compare:\u003cbr\u003eMOV: transfer\u003cbr\u003eCML: Inverted transmission\u003cbr\u003eXCH: Exchange\u003cbr\u003eBCD: Binary conversion to BCD\u003cbr\u003eBIN: Convert BCD code to binary\u003cbr\u003eCMP: Comparison\u003cbr\u003eZCP: Interval comparison\u003cbr\u003eFMOV: Multicast\u003cbr\u003eSMOV: Bit transfer\u003cbr\u003eBMOV: batch delivery\u003cbr\u003e\u003cbr\u003eArithmetic and Logical Operations:\u003cbr\u003eADD: Binary addition operation\u003cbr\u003eSUB: Binary subtraction operation\u003cbr\u003eMUL: Binary multiplication operation\u003cbr\u003eDIV: Binary division operation\u003cbr\u003eINC: Binary plus 1 operation\u003cbr\u003eDEC: Binary minus 1 operation\u003cbr\u003eWAND: Word Logic And\u003cbr\u003eWOR: Word logical OR\u003cbr\u003eWXOR: Word logic exclusive OR\u003cbr\u003eNEG: Find two's complement\u003cbr\u003e\u003cbr\u003eBit Data Processing:\u003cbr\u003eZRST: Word shift left\u003cbr\u003eDECO: Decoding\u003cbr\u003eENCO: Encoding\u003cbr\u003e\u003cbr\u003eCycle and Displacement:\u003cbr\u003eSFTR: bit shift right\u003cbr\u003eSFTL: bit shift left\u003cbr\u003eSFWR: FIFO (first in first out) write\u003cbr\u003eSFRD: FIFO (first in first out) read\u003cbr\u003e\u003cbr\u003eHigh-Speed Processing:\u003cbr\u003eREF: Input and output refresh\u003cbr\u003eREFF: Input filter time adjustment\u003cbr\u003eMTR: Matrix input\u003cbr\u003eHSCS: Compare set (for high-speed counting)\u003cbr\u003eHSCR: Comparison reset (for high-speed counting)\u003cbr\u003eSPD: Pulse density\u003cbr\u003ePLSY: Specified frequency pulse output\u003cbr\u003ePWM: Pulse width modulation output\u003cbr\u003ePLSR: With acceleration and deceleration pulse output\u003cbr\u003e\u003cbr\u003eConvenient Instructions:\u003cbr\u003eIST: State initialization\u003cbr\u003eABSD: Cam control (absolute)\u003cbr\u003eINCD: Cam control (incremental)\u003cbr\u003eALT: Alternate output\u003cbr\u003eRAMP: ramp signal\u003cbr\u003e\u003cbr\u003ePeripheral I\/O Device Port:\u003cbr\u003eDSW: BCD digital switch input\u003cbr\u003eSEGL: Seven-segment code time-sharing display\u003cbr\u003eFROM: BFM read\u003cbr\u003eTO: BFM write\u003cbr\u003e\u003cbr\u003ePeripheral Equipment:\u003cbr\u003eRS: Serial data transmission\u003cbr\u003ePRUN: octal digit transmission (#)\u003cbr\u003eASCI: Convert hexadecimal number to ASCI code\u003cbr\u003eHEX: Convert ASCI code to hexadecimal number\u003cbr\u003eCCD: Check\u003cbr\u003eVRRD: Potentiometer variable input\u003cbr\u003eVRSC: Potentiometer variable interval\u003cbr\u003ePID: PID calculation\u003cbr\u003e\u003cbr\u003ePositioning:\u003cbr\u003eABS: ABS current value read\u003cbr\u003eZRN: Return to origin\u003cbr\u003ePLSV: Variable speed pulse output\u003cbr\u003eDRVI: Relative position control\u003cbr\u003eDRVA: Absolute position control\u003cbr\u003e\u003cbr\u003eClock Operation:\u003cbr\u003eTCMP: Clock data comparison\u003cbr\u003eTZCP: Clock data interval comparison\u003cbr\u003eTADD: Clock data addition\u003cbr\u003eTSUB: Clock data subtraction\u003cbr\u003eTRD: Clock data read\u003cbr\u003eTWR: Clock data write\u003cbr\u003eHOUR: Chronograph\u003cbr\u003e\u003cbr\u003eContact Comparison:\u003cbr\u003eLD: (S1)=(S2) when the starting contact is on\u003cbr\u003eLD\u0026gt;: (S1)\u0026gt;(S2) when the starting contact is on\u003cbr\u003eLD\u0026lt;: (S1) \u0026lt;(S2) when the starting contact is on\u003cbr\u003eLD\u0026lt;\u0026gt;: (S1)\u0026lt;\u0026gt;(S2) when the starting contact is on\u003cbr\u003eLD≦: (S1)≦(S2) When the starting contact is on\u003cbr\u003eLD≥: (S1)≥(S2) when the starting contact is on\u003cbr\u003e\u003cbr\u003eAND=: (S1)=(S2) when the series contact is on\u003cbr\u003eAND\u0026gt;: (S1)\u0026gt;(S2) when the series contact is on\u003cbr\u003eAND\u0026lt;: (S1)\u0026lt;(S2) when the series contact is on\u003cbr\u003eAND\u0026lt;\u0026gt;: (S1)\u0026lt;\u0026gt;(S2) when the series contact is on\u003cbr\u003eAND≤: When (S1)≤(S2), the series contacts are connected\u003cbr\u003eAND≥: When (S1)≥(S2), the series contact is on\u003cbr\u003e\u003cbr\u003eOR=: (S1)=(S2) when the parallel contacts are connected\u003cbr\u003eOR\u0026gt;: (S1)\u0026gt;(S2), the parallel contacts are connected\u003cbr\u003eOR\u0026lt;: When (S1)\u0026lt;(S2), the parallel contacts are connected\u003cbr\u003eOR\u0026lt;\u0026gt;: (S1)\u0026lt;\u0026gt;(S2), the parallel contacts are connected\u003cbr\u003eOR≤: When (S1)≤(S2), the parallel contacts are connected\u003cbr\u003eOR≥: When (S1)≥(S2), the parallel contacts are connected\u003cbr\u003e\u003cb\u003e\u003cbr\u003eSpecial Component Description:\u003c\/b\u003e\u003cbr\u003eM8000: RUN monitoring (always open during RUN)\u003cbr\u003eM8002: Initialization pulse (normally open scan cycle flag)\u003cbr\u003eM8004: Error prompt (PLC error)\u003cbr\u003eM8012: 100ms clock (oscillate with 100ms period)\u003cbr\u003eM8014: 1 min clock (oscillate with 1 min period)\u003cbr\u003eM8021: Dislocation mark\u003cbr\u003eM8029: instruction execution end\u003cbr\u003eM8034: disable output\u003cbr\u003e\u003cbr\u003eM8001: RUN monitoring (normally closed during RUN)\u003cbr\u003eM8003: Initialization pulse (normally closed scan cycle flag)\u003cbr\u003eM8011: 10ms clock (oscillate with 10ms period)\u003cbr\u003eM8013: 1s clock (oscillates in 1S period)\u003cbr\u003eM8020: Zero mark (operation mark for application instructions)\u003cbr\u003eM8022: Carry flag\u003cbr\u003eM8033: Memory storage\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSummary of Soft Element Function:\u003c\/b\u003e\u003cbr\u003eAuxiliary Relay:\u003cbr\u003eGeneral use: M0-M383, 384 points\u003cbr\u003eKeep use: M384-M1535, 1152 points\u003cbr\u003eSpecial use: M8000-M8255, 256 points\u003cbr\u003e\u003cbr\u003eStatus Register:\u003cbr\u003eInitial state: S0-S9, 10 points\u003cbr\u003eGeneral status: S10-S127, 118 points\u003cbr\u003eSave area: S128-S899, 772 points\u003cbr\u003e\u003cbr\u003eTimer:\u003cbr\u003e100MS: T0-T199, 200 points\u003cbr\u003e10MS: T200-T245, 46 points\u003cbr\u003e1MS cumulative type: T246-T249, 4 points\u003cbr\u003e100MS cumulative type: T250-T256, 6 points\u003cbr\u003e\u003cbr\u003eCounter:\u003cbr\u003e16-bit increment (general use): C0-C15, 16 points\u003cbr\u003e16-bit increment (for holding): C16-C199, 184 points\u003cbr\u003e32-bit reversible (general use): C200-C219, 20 points\u003cbr\u003e32-bit reversible (for holding): C220-C234, 15 points\u003cbr\u003e32-bit reversible (for high-speed retention): C235-C255, 8 points\u003cbr\u003e\u003cbr\u003eData Register:\u003cbr\u003e16-bit general use: D0-D127, 128 points\u003cbr\u003e16-bit retention: D128-D2300, 2172 points\u003cbr\u003e16-bit special use: D8000-D8255, 20 points\u003cbr\u003eFor 16-bit indexing: V0-V7 Z0-Z7, 15 points\u003cbr\u003e\u003cbr\u003eNested Pointers:\u003cbr\u003eFor skip subroutine, branch: P0-P127, 128 points\u003cbr\u003eMain control: N0-N7, 8 points\u003cbr\u003e\u003cbr\u003eConstant:\u003cbr\u003eDecimal (K): 16-32768 to +32767, 32-bit\u003cbr\u003eHexadecimal (H): 16 bits: 0~FFFFH, 32 bits: 0~FFFFFFFFH\u003cbr\u003e\u003c\/p\u003e","brand":"Thanksbuyer","offers":[{"title":"Default Title","offer_id":40826184597553,"sku":"68730","price":49.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/4790\/6353\/files\/7077354602545_watermarked_0.jpg_0.png?v=1767921180","url":"https:\/\/www.thanksbuyer.com\/products\/fx1n-30mt-plc-controller-programmable-logic-controller-direct-download-transistor-output-with-shell","provider":"Thanksbuyer Online,SDR Radio, Testers and Measurement devices, Astronomy products,  Audio Amplifer and Decoders","version":"1.0","type":"link"}