{"product_id":"fx3u-32mt-plc-programmable-logic-controller-board-high-speed-input-output-6ad-2da-support-for-modbus","title":"FX3U-32MT PLC Programmable Logic Controller Board High-Speed Input Output 6AD-2DA Support For MODBUS","description":"\u003cp\u003e\u003cb\u003eAdvantages:\u003c\/b\u003e\u003cbr\u003e- 16 inputs 16 outputs\u003cbr\u003e- 6AD+2DA\u003cbr\u003e- High-speed input and output\u003cbr\u003e- Support PID\u003cbr\u003e\u003cbr\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003e- Industrial control board\u003cbr\u003e- Original chip\u003cbr\u003e- Stable performance\u003cbr\u003e- Online Download\u003cbr\u003e- Online monitoring\u003cbr\u003e- MT transistor type: Support pulse output. Only support DC24V load. Output current up to 1A\u003cbr\u003e- Can be used in various industrial automation control\u003cbr\u003e- Suitable for metallurgy, printing, chemicals, plastics, building materials, home furnishing, packaging, textiles, food\u003cbr\u003e\u003cbr\u003e\u003cb\u003eProduct Parameters:\u003c\/b\u003e\u003cbr\u003e- Product name: industrial control board\u003cbr\u003e- Product model: FX3U-32MT\u003cbr\u003e- Product number: 14500\u003cbr\u003e- Output type: Transistor output\u003cbr\u003e- Input points: 16 points\u003cbr\u003e- Output points: 16 points\u003cbr\u003e- Supply voltage: 24V DC\u003cbr\u003e- Output current: 1A\u003cbr\u003e- Analog input: 6AD\u003cbr\u003e- Analog output: 2DA\u003cbr\u003e- High-speed counting: 6 channels 3K. Optional 6 channels 60K \u003cbr\u003e- Pulse output: Default 8\/ 10K. Optional 8\/ 100K\u003cbr\u003e- Floating point: support\u003cbr\u003e- Stepper motor: Support\u003cbr\u003e- Memory capacity: 8000 steps\u003cbr\u003e- Download method: Direct download\u003cbr\u003e- RS485 communication port: optional\u003cbr\u003e- For MODBUS: optional\u003cbr\u003e- Connect text screen: support\u003cbr\u003e- Connect the touch screen: support\u003cbr\u003e- Programming software: For GX Developer or GX Works2\u003cbr\u003e- Installation method: fixed isolation column installation\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoft Element:\u003c\/b\u003e\u003cbr\u003e- Intermediate relay M: M0-M3071, power-down storage range can be set\u003cbr\u003e- Step point S: S0-1023, power-down saving range can be set to S0-S1023\u003cbr\u003e- 100MS timer: T0-T199, accumulative power-down save T184-T199\u003cbr\u003e- 10MS timer: T200-T249, accumulative power-off save T246-T249\u003cbr\u003e- 1MS timer: T250-T383, of which T250-255 is cumulative\u003cbr\u003e- 16-bit counter: C0-C199, save C100-199 when power off\u003cbr\u003e- 32-bit counter: C200-C219, save C220-C234 when power off\u003cbr\u003e- 32-bit high-speed counter:\u003cbr\u003e  C235-255; C235-240 is a single-phase counter without frequency multiplication;\u003cbr\u003e  C241-240 is a single-phase counter, 2 times the frequency;\u003cbr\u003e  C247-249 is a two-phase counter without frequency multiplication;\u003cbr\u003e  C250-252 is a two-phase counter, 2 times the frequency;\u003cbr\u003e  C253-255 is a two-phase counter, 4 times the frequency;\u003cbr\u003e- Register D: D0-D7999, the saving range can be set to D0-7999 after power-off,\u003cbr\u003e- Indirect addressing pointer V, Z: V0-7, Z0-7\u003cbr\u003e- P subroutine jump number: P0-63\u003cbr\u003e- I Interrupt: X0-5 external interrupt. Timer interrupt (1MS as a unit). The counter is interrupted.\u003cbr\u003e- Special M element: M8000 is normally closed when running, M8002 is power-on pulse, M8011 is 10Ms pulse, M8012 is 100Ms pulse, M8013 is 1s pulse, and M8014 is minute pulse.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eInstruction List:\u003c\/b\u003e\u003cbr\u003e\u003cu\u003eBasic instructions:\u003c\/u\u003e\u003cbr\u003eLD: Normally open contact at the start of operation\u003cbr\u003eLDI: Normally closed contact at the start of operation\u003cbr\u003eLDP: Rising edge detection operation starts\u003cbr\u003eLDF: Falling edge detection operation starts\u003cbr\u003eAND: series normally open contact\u003cbr\u003eANI: Series normally closed contact\u003cbr\u003eANDP: Series connection detected on rising edge\u003cbr\u003eANDF: Falling edge detection of series connection\u003cbr\u003eOR: Parallel normally open contacts\u003cbr\u003eORI: Parallel normally closed contacts\u003cbr\u003eORP: parallel connection detected by rising edge\u003cbr\u003eORF: Falling edge detection parallel connection\u003cbr\u003eANB: Series connection between circuit blocks\u003cbr\u003eORB: parallel connection between circuit blocks\u003cbr\u003eOUT: Coil output drive\u003cbr\u003eSET: keep the coil action\u003cbr\u003eRST: Release the coil operation hold\u003cbr\u003ePLS: Coil rising edge output\u003cbr\u003ePLF: Coil falling edge output\u003cbr\u003eALT: alternate output\u003cbr\u003eMC: Coil for common string connection point\u003cbr\u003eMCR: Common contact release command\u003cbr\u003eMPS: Operational storage\u003cbr\u003eMRD: storage read\u003cbr\u003eMPP: memory read and reset\u003cbr\u003eINV: Invert the result of the operation\u003cbr\u003eEND: end of program\u003cbr\u003eSTL: start of step ladder diagram\u003cbr\u003eRET: End of step ladder diagram\u003cbr\u003eCALL: call subroutine\u003cbr\u003eSRET: Subroutine return\u003cbr\u003e\u003cbr\u003e\u003cu\u003eProcedure Flow:\u003c\/u\u003e\u003cbr\u003eCJ: Conditional jump\u003cbr\u003eCALL: subroutine call\u003cbr\u003eSRET: Subroutine return\u003cbr\u003eFEND: End of main program\u003cbr\u003e\u003cbr\u003e\u003cu\u003eSend and Compare:\u003c\/u\u003e\u003cbr\u003eCMP: Comparison\u003cbr\u003eZCP: Regional comparison\u003cbr\u003eMOV: transfer\u003cbr\u003eCML: Reverse transmission\u003cbr\u003eBMOV: send together\u003cbr\u003eFMOV: Multicast\u003cbr\u003eXCH: Exchange\u003cbr\u003eBCD: BCD conversion\u003cbr\u003eBIN: BIN conversion\u003cbr\u003e\u003cbr\u003e\u003cu\u003eFour Logical Operations:\u003c\/u\u003e\u003cbr\u003eADD: BIN addition\u003cbr\u003eSUB: BIN subtraction\u003cbr\u003eMUL: BIN multiplication\u003cbr\u003eDIV: BIN division\u003cbr\u003eINC: BIN plus 1\u003cbr\u003eDEC: BIN minus 1\u003cbr\u003eWAND: logical word and\u003cbr\u003eWPR: logical word or\u003cbr\u003eWXOR: logical word exclusive OR\u003cbr\u003eNEG: complement\u003cbr\u003e\u003cbr\u003e\u003cu\u003eCycle Displacement:\u003c\/u\u003e\u003cbr\u003eROR: right shift cycle\u003cbr\u003eROL: Shift left loop\u003cbr\u003eRCR: right shift\u003cbr\u003eRCL: Left shift\u003cbr\u003eSFTL: bit shift left\u003cbr\u003eSFTR: bit shift right\u003cbr\u003e\u003cbr\u003e\u003cu\u003eSpecial Components Instruction:\u003c\/u\u003e\u003cbr\u003eM8000: Normally closed during operation\u003cbr\u003eM8002: Power-on pulse\u003cbr\u003eM8011: 10Ms pulse\u003cbr\u003eM8012: 100Ms pulse\u003cbr\u003eM8013: 1s pulse\u003cbr\u003eM8014: is the minute pulse\u003cbr\u003e\u003cbr\u003eZRST: Batch reset\u003cbr\u003eMEAN: Average\u003cbr\u003eFLT: BIN, integer → 2, hexadecimal floating point number conversion\u003cbr\u003eGRY: BIN, integer → gray code conversion\u003cbr\u003eGBIN: Gray code → BIN, integer\u003cbr\u003e\u003cbr\u003eDHSCS: High-speed comparison set\u003cbr\u003eDHSCR: High-speed comparison reset\u003cbr\u003eSPD: Pulse density, pulse width (pulse interval time) can also be measured\u003cbr\u003ePLSY: Pulse output\u003cbr\u003ePLSV: Pulse output with direction control\u003cbr\u003ePWM: Pulse width modulation, 0-32767us\u003cbr\u003ePLSR: Pulse output with acceleration and deceleration\u003cbr\u003eDRVA: Absolute position control\u003cbr\u003eDRVI: Relative position control\u003cbr\u003eABSD: Cam control (absolute method)\u003cbr\u003e\u003cbr\u003eRS: Serial data transmission\u003cbr\u003eASCI: HEX-ASCII conversion\u003cbr\u003eHEX: ASCII-HEX conversion\u003cbr\u003eCCD: check code\u003cbr\u003ePID: PID calculation\u003cbr\u003eSEGD: BCD to 7-segment digital tube\u003cbr\u003e\u003cbr\u003eECMP: Comparison of binary floating-point numbers\u003cbr\u003eEZCP: Interval comparison of binary floating point numbers\u003cbr\u003eEBIN: decimal floating point number-2, conversion of decimal floating point number\u003cbr\u003eEADD: Addition of binary floating-point numbers\u003cbr\u003eESUB: binary floating-point number subtraction\u003cbr\u003eEMUL: Binary floating point number multiplication\u003cbr\u003eEDIV: Division of binary floating-point numbers\u003cbr\u003eINT: Binary floating point number -BIN, integer conversion\u003cbr\u003eSIN: floating-point number SIN operation\u003cbr\u003eTAN: Floating point number TAN operation\u003cbr\u003eCOS: Floating point COS operation\u003cbr\u003eASIN: floating-point number SIN-1 operation\u003cbr\u003eEXP: binary floating point exponential operation\u003cbr\u003eLOGE: natural logarithm operation of binary floating-point numbers\u003cbr\u003eLOGE10: Commonly used logarithmic operations of binary floating-point numbers\u003cbr\u003e\u003cbr\u003eSWAP: Up and down byte conversion\u003cbr\u003e\u003cbr\u003eSER: data search\u003cbr\u003eALT: alternate output\u003cbr\u003eRAMP: ramp signal\u003cbr\u003eBON: ON bit judgment\u003cbr\u003eSUM: ON digits\u003cbr\u003eANS: Alarm set\u003cbr\u003eANR: Alarm reset\u003cbr\u003eHOUR: Chronograph\u003cbr\u003e\u003cbr\u003eTCMP: Clock data comparison\u003cbr\u003eTRD: Clock data read\u003cbr\u003eTWR: clock data write\u003cbr\u003e\u003cbr\u003eLD=: (S1=(S2)\u003cbr\u003eLD\u0026gt;: (S1)\u0026gt;(S2)\u003cbr\u003eLD\u0026lt;: (S1)\u0026lt;(S2)\u003cbr\u003eLD◇: (S1)≠(S2)\u003cbr\u003eLD≤: (S1)≤(S2)\u003cbr\u003eLD≥: (S1)≥(S2)\u003cbr\u003eAND=: (S1=(S2)\u003cbr\u003eAND\u0026gt;: (S1)\u0026gt;(S2)\u003cbr\u003eAND\u0026lt;: (S1)\u0026lt;(S2)\u003cbr\u003eAND◇: (S1)≠S2)\u003cbr\u003eAND≤: (S1)≤(S2)\u003cbr\u003eAND≥: (S1)≥(S2)\u003cbr\u003eOR=: (S1=(S2)\u003cbr\u003eOR\u0026gt;: (S1)\u0026gt;(S2)\u003cbr\u003eOR\u0026lt;: (S1)\u0026lt;(S2)\u003cbr\u003eOR◇: (S1)≠(S2)\u003cbr\u003eOR≤: (S1)≤(S2)\u003cbr\u003eOR≥: (S1)≥(S2)\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePackage Included:\u003c\/b\u003e\u003cbr\u003e- 1 x Set of PLC Controller\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cb\u003eNote: Programming cable is not included. Please purchase separately.\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg style=\"width: 750px;\" src=\"https:\/\/www.byimg.com\/catalog\/68713\/68713-01.jpg\"\u003e\u003cbr\u003e\u003cimg style=\"width: 750px;\" src=\"https:\/\/www.byimg.com\/catalog\/68713\/68713-02.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eHow To Fix:\u003c\/b\u003e\u003cbr\u003eThe installation method of the base of the PLC industrial control board: use four screws to fix the base. Each PLC board has holes on the four corners for fixing installation holes, and each board has 4 screws and a bottom seat.\u003cbr\u003e\u003cimg style=\"width: 750px;\" src=\"https:\/\/www.byimg.com\/catalog\/68713\/68713-03.jpg\"\u003e\u003cbr\u003e\u003cb\u003eApplication Example:\u003c\/b\u003e\u003cbr\u003e\u003cimg style=\"width: 750px;\" src=\"https:\/\/www.byimg.com\/catalog\/68713\/68713-04.jpg\"\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Thanksbuyer","offers":[{"title":"Default Title","offer_id":40826177355825,"sku":"68713","price":49.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/4790\/6353\/files\/7077351489585_watermarked_0.jpg_0.png?v=1767922209","url":"https:\/\/www.thanksbuyer.com\/products\/fx3u-32mt-plc-programmable-logic-controller-board-high-speed-input-output-6ad-2da-support-for-modbus","provider":"Thanksbuyer Online,SDR Radio, Testers and Measurement devices, Astronomy products,  Audio Amplifer and Decoders","version":"1.0","type":"link"}