{"product_id":"used-pcie-6321-daq-data-acquisition-original-io-module-781044-01-for-ni-national-instruments","title":"Used PCIe-6321 DAQ Data Acquisition Original IO Module 781044-01 for NI National Instruments","description":"\u003cb\u003eUsed PCIe-6321 DAQ Data Acquisition Original IO Module 781044-01 for NI National Instruments\u003cbr\u003e\u003cbr\u003eAdvantages: \u003c\/b\u003e\u003cbr\u003e- 16 analog inputs, 250kS\/s, 16-bit resolution, ±10 V\u003cbr\u003e- 2 analog outputs, 900kS\/s, 16-bit resolution, ±10 V\u003cbr\u003e- 24 digital I\/O lines (8 of which are 1 MHz hardware timing lines)\u003cbr\u003e- 4-channel 32-bit counters\/timers for PWM, encoder, frequency, event counting, etc.\u003cbr\u003e- Advanced timing and triggering with NI-STC3 timing and synchronization technology\u003cbr\u003e- Supports operating systems for Windows 7\/Vista\/XP\/2000\u003cbr\u003e\u003cbr\u003e\u003cb\u003eDescription:\u003c\/b\u003e\u003cbr\u003eThe X-Series Multifunction Data Acquisition (DAQ) devices take performance to new heights with a high-power PCI Express bus, NI-STC3 timing and synchronization technology, and multi-core optimized drivers and application software. \u003cbr\u003e\u003cbr\u003ePCI Express bus with high processing power\u003cbr\u003ePCI Express offers up to 250 MB\/s dedicated bandwidth to connect devices from all directions; X-Series devices use an optimized native PCI Express interface for high throughput and low latency.\u003cbr\u003e\u003cbr\u003eNI-STC3 technology\u003cbr\u003eNI-STC3 timing and synchronization technology provides advanced timing capabilities, including: independent analog and digital timing engines, retriggerable measurement tasks, and 4 counters\/timers with more functionality than ever before. \u003cbr\u003e\u003cbr\u003eData acquisition software\u003cbr\u003eThe multi-threaded NI-DAQmx driver software included with the X Series devices is compatible with the following application software versions (or later) for NI – for LabVIEW 8.2, LabWindows\/CVI 7.x, or Measurement Studio 7.x; LabVIEW SignalExpress 1.x; Or LabVIEW with LabVIEW Real-Time Module 8.2. X-Series devices are also compatible with C\/C++ and Microsoft Visual Studio .NET. NI-DAQmx includes free LabVIEW SignalExpress LE data logging software and hundreds of examples to start your application development.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecifications:     \u003c\/b\u003e\u003cbr\u003eGeneral:\u003cbr\u003e- Product Family: multifunctional DAQ    \u003cbr\u003e- Measurement Type: Digit; Voltage; phase difference coding; frequency\u003cbr\u003e- Form Factor: PCI Express    \u003cbr\u003e- Operating System \/ Target: for Windows real-time system    \u003cbr\u003e- RoHS Compliant: Yes\u003cbr\u003e- Isolation Type: None\u003cbr\u003e\u003cbr\u003eAnalog Input:\u003cbr\u003e- Single-Ended Channels: 16        \u003cbr\u003e- Differential channels: 8    \u003cbr\u003e- Analog input resolution: 16 bits    \u003cbr\u003e- Maximum voltage range: Range -10 V to 10 V; Accuracy 2.2 mV\u003cbr\u003e- Minimum Voltage Range: Range -0.2 V to 0.2 V; Accuracy 69 μV\u003cbr\u003e- Number of Ranges: 4        \u003cbr\u003e- Simultaneous Sampling: No    \u003cbr\u003e\u003cbr\u003eAnalog Output:\u003cbr\u003e- Number of Channels: 2        \u003cbr\u003e- Resolution: 16 bits        \u003cbr\u003e- Maximum Voltage Range: Range -10 V to 10 V; Accuracy 3.27 mV\u003cbr\u003e- Update Rate: 900kS\/s    \u003cbr\u003e- Current Drive Single: 5 mA\u003cbr\u003e\u003cbr\u003eDigital I\/O:\u003cbr\u003e- Bidirectional Channels: 24        \u003cbr\u003e- Input-Only Channels: 0\u003cbr\u003e- Output-Only Channels: 0\u003cbr\u003e- Timing: Hardware; software    \u003cbr\u003e- Clocked Lines: 8\u003cbr\u003e- Maximum Clock Rate: 1 MHz        \u003cbr\u003e- Logic Levels: TTL    \u003cbr\u003e- Programmable Input Filters: Yes\u003cbr\u003e- Supports Programmable Power-Up States?: Yes\u003cbr\u003e        \u003cbr\u003eDigital Input:\u003cbr\u003e- Input Type:\u003cbr\u003e- Maximum Voltage Range: 0V-5V\u003cbr\u003e    \u003cbr\u003eDigital Output:\u003cbr\u003e- Output Type: drain; source current    \u003cbr\u003e- Current Drive Single: 24 mA    \u003cbr\u003e- Current Drive All: 576 mA\u003cbr\u003e- Maximum Voltage Range: 0V-5V\u003cbr\u003e\u003cbr\u003eCounters \/ Timers:\u003cbr\u003e- Watchdog Timer: Yes    \u003cbr\u003e- Counters: 4        \u003cbr\u003e- Number of DMA Channels: 8\u003cbr\u003e- Buffered Operations: Yes\u003cbr\u003e- Debouncing \/ Glitch Removal: Yes\u003cbr\u003e- Max Source Frequency: 100 MHz    \u003cbr\u003e- Pulse Generation: Yes\u003cbr\u003e- Size: 32 bits    \u003cbr\u003e- Time-base Stability: 50 ppm    \u003cbr\u003e- Logic Levels: 5V\u003cbr\u003e    \u003cbr\u003eTiming \/ Triggering \/ Synchronization:\u003cbr\u003e- Triggering: digit    \u003cbr\u003e- Synchronization Bus (RTSI): Yes\u003cbr\u003e    \u003cbr\u003ePhysical Specifications:\u003cbr\u003e- Length: 16.8cm\/6.6\"    \u003cbr\u003e- Width: 50mm\/2\"\u003cbr\u003e- Height: 9.9cm\/3.9\"\u003cbr\u003e- I\/O Connector: 68-pin VHDCI female connector\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePackage Included:\u003c\/b\u003e\u003cbr\u003e- 1 x Data Acquisition\u003cbr\u003e","brand":"Thanksbuyer Online,SDR Radio, Testers and Measurement devices, Astronomy products, Audio Amplifer and Decoders","offers":[{"title":"Default Title","offer_id":41028245979185,"sku":"79045","price":1216.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/4790\/6353\/files\/1667444986-1.jpg?v=1780305788","url":"https:\/\/www.thanksbuyer.com\/ru\/products\/used-pcie-6321-daq-data-acquisition-original-io-module-781044-01-for-ni-national-instruments","provider":"Thanksbuyer Online,SDR Radio, Testers and Measurement devices, Astronomy products,  Audio Amplifer and Decoders","version":"1.0","type":"link"}