Vector Network Analyzer KC901C+ 2GHZ RF Multimeter / Single-Port Network Tester
Please contact us for Manual Download Link
Description:
- KC901C+ is a multipurpose RF instrument integrating a VNA (vector network analyzer), spectrum analyzer, field strength meter, and an extra low-frequency signal source. It can do complete single port vector measurement and 2-ports simple vector network analyzing.
KC901C+ is the upgrade of KC901C.
- Rf multi-purpose table, as a general subject function is still a single port vector network analyzer (VNA, S11), and support vector transmission of simple, field intensity, frequency spectrum, radio frequency signal source, audio signal source, and other functions.
Specifications:
- 9KHz-2GHz frequency range
- 1Hz frequency step
- Full digital intermediate frequency
- Reliable accuracy and stability
- Strong anti-interference ability
- Rich functional and lightweight design
Main functions
- Transmission test (scalar: debug filter, amplifier, test antenna directivity, vector: basic phase change trend)
- Reflection test (vector: debug impedance matching, check the quality of the antenna feed system)
- Spectrum display and field observation ** (test radio emission performance, find source of interference)
- A signal that outputs a particular frequency point separately
Recommended application
- KC901C+ is mainly used to detect, debug the rf circuit and the day feeder system.
- In most frequency range, it can also conduct field strength measurement, interference finding and other work.
- The device is lightweight and powerful, and can easily be transferred to the site with measurements that have previously been completed by a large laboratory instrument.
- 901C+ is an electronic engineer's worth of testing tools, as well as a standing equipment for professional communication engineering and broadcast television station technicians.
* the technical parameters published shall prevail. ** informal functions
|
Test |
test condition |
Parameter |
Note |
||
|
Min |
Typical |
Max |
|||
|
Frequency range |
effective |
9KHz |
|
2GHz |
|
|
SPEC |
0 |
|
2GHz |
|
|
|
Scan range |
SPAN |
1KHz |
|
2GHz |
|
|
Scan points |
|
450pt |
|
3150pt |
|
|
Frequency resolution |
All scanning functions |
|
1Hz |
|
|
|
Low frequency signal source |
|
0.1Hz |
|
|
|
|
Level resolution |
|
0.01dB |
|
|
|
|
Phase resolution |
|
0.01° |
|
|
|
|
Scan speed |
RBW=30KHz |
|
1.3ms |
|
|
|
RBW=10KHz |
|
1.5ms |
|
|
|
|
RBW=3KHz |
|
2.4ms |
|
|
|
|
RBW=1KHz |
|
4ms |
|
|
|
|
RBW=30K,450pt |
|
0.6s |
|
|
|
|
Output
|
1MHz-2GHz |
-20dBm |
-6dBm |
0dBm |
Port1 |
|
1MHz-2GHz |
-6dBm |
3dBm |
10dBm |
Port2 |
|
|
|
|
|
|
|
|
|
Maximum output level |
1MHz-2GHz Signal |
0Bm |
10dBm |
13dBm |
Port2 |
|
Output signal |
RF |
0dB |
|
25dB |
Port2 |
|
0dB |
|
55dB |
Port1 |
||
|
Sensitivity |
1MHz-2GHz |
-107dBm |
|
|
Port1 RBW=1KHz |
|
|
|
|
|
||
|
The available dynamic range of the transmission measurement |
1MHz-1GHz |
|
80dB |
|
|
|
1GHz-2GHz |
|
60dB |
|
||
|
|
|
|
|
||
|
Amplitude uncertainty of transmission measurement |
After straight-through calibration, when the insertion loss is L<60dB |
|
0.5+0.05L |
||