Mechanical Parameters:
- Power supply: 9 - 28V (typ. 12/24V), over-voltage/over-current/anti reverse connection protection
- Working temperature: -30℃ to 75℃
- Working humidity: 5% - 95% non-condensing
- Protection level: IP20
- Station type: ModbusTCP slave
- Communication method: ModbusTCP
- Communication interface: RJ45, 10/100 adaptive
- Maximum bus length: 100m
- Configuration method: ModbusTCP protocol

Indicator Description:
- PWR: indicate power status, normally on
- SY1: system light, normally on when the program runs
- SY2: meaningless
- P0: flashing after successful communication with the master station indicates normal communication between the core board and IO module

Top Terminal Description:

- V+: positive power input
- V-: negative power input
- PE: grounding
- NC: reserved, do not connect
- NET: network port

Default Value after DAP Module Restart:
- Device address: 192.168.1.37
- Subnet mask: 255.255.255.0
- Gateway address: 192.168.1.1
- MAC address: 00:50:43:74:18:51, each device is different and generally does not require modification
- Timeout offline: 0 (how long does it take to receive instructions from the master station and determine it as offline); 0 means this feature is not enabled
- Heartbeat timeout: 0 (how long does it take to receive the Client command and disconnect the socket connection); 0 means this feature is not enabled
- Webpage account: admin
- Webpage password: admin

Reset Button:
- The reset button under the ModbusTCP core board is used to restore factory settings. When the user forgets the current IP address and cannot communicate or configure, long press the RST button until the SYS light keeps flashing. The DAP module restarts and runs with default parameters.

Package Included:
- 1 x Core Board