• CO2 Detector Meter TVOC Indoor Carbon Dioxide Detector Organic Matter Gas Concentration Detector
  • CO2 Detector Meter TVOC Indoor Carbon Dioxide Detector Organic Matter Gas Concentration Detector
  • CO2 Detector Meter TVOC Indoor Carbon Dioxide Detector Organic Matter Gas Concentration Detector
  • CO2 Detector Meter TVOC Indoor Carbon Dioxide Detector Organic Matter Gas Concentration Detector
  • CO2 Detector Meter TVOC Indoor Carbon Dioxide Detector Organic Matter Gas Concentration Detector

CO2 Detector Meter TVOC Indoor Carbon Dioxide Detector Organic Matter Gas Concentration Detector

Availability: Out Of Stock

  • Price:$35.35
  • Price in reward points: 354 Reward Points: 4
  • Quantity 3+ units 10+ units 30+ units 50+ units More
    Price /Unit $34.64 $33.94 $32.88 $31.46 Contact US
Quantity:

CO2 Detector Meter TVOC Indoor Carbon Dioxide Detector Organic Matter Gas Concentration Detector

CO2_SGP30_C Manual:

1. Overview:
1.1. Power supply: Micro USB 5V/1A
1.2. Use metal oxide semiconductor SGP30 gas sensor
1.3. Function: CO2, TVOC detection
1.4. No calibration required
1.5. Accuracy: ±25% of reading
1.6. Detection range: TVOC: 0~10000ppb, CO2: 400~10000ppm
1.7. Update data every 2 seconds

2. Display Instructions:
2.1. CO2:
* 400~600ppm Good
* 601~1000ppm OK
* 1000~2000ppm Bad
* More than 2000ppm So Bad

The concentration of CO2 and the physiological response of the human body are as follows (for reference only):
* 350~450ppm same as general outdoor environment;
* 350~1000ppm fresh air and smooth breathing;
* 1000~2000ppm I feel the air is muddy and start to feel drowsy;
* 2000~5000ppm headache, lethargy, sluggishness, inability to concentrate, rapid heartbeat, mild nausea;
* More than 5000ppm may cause severe hypoxia, causing permanent brain damage, coma, and even death.

2.2. TVOC (Total Volatile Organic Compounds):
* 0~500ppb Good
* 501~600ppb OK
* Greater than 600ppb Bad

3. Precautions:
3.1. It takes about 16 seconds to boot up.
3.2. The sensor is a sensitive gas sensor, please do not approach the human body (human breathing), and do not place it on the surface of odorous objects.
3.3. Do not place and use in an environment where the gas exceeds the range.
3.4. If it has not been powered on for a long time (more than 7 days), it must be used after 24 hours of continuous power on.
3.5. The effect will be better after 1 hour of continuous power on for the first time.
3.6. When changing the environment, it is better to observe the data after standing still for 10 minutes.
3.7. For sensitive sensors, it is normal for the detection data to fluctuate.
3.8. Due to accuracy limitations and the influence of ambient gas, the test results are for reference only.